Ultrasonic Cell Disruptor
Ultrasonic Cell Disruptor
Application:
Widely used in the field such as biology, chemistry. microbiology, pharmacology. physics, zoology, agronomy, medical science, pharmacy for teaching, scientific research, and production. Features:
|
Technical Parameters:
Model |
UCD-150 |
UCD-250 |
UCD-500 |
UCD-650 |
UCD-950 |
UCD-1200 |
UCD-1500 |
UCD-1800 |
UCD-2000 |
Frequency (KHz) |
20~25 |
20~25 |
20~25 |
20~25 |
20~25 |
19.5~20.5 |
19.5~20.5 |
19.5~20.5 |
19.5~20.5 |
Crushing Capacity (ml) |
0.2~150 |
0.2~250 |
0.2~400 |
0.2~500 |
0.2~700 |
10~1000 |
50~1500 |
50~1800 |
50~2000 |
Standard Amplitude-change Pole Ø (mm) |
6 |
6 |
6 |
6 |
6 |
20 |
22 |
22 |
25 |
Optional Amplitude-change Pole Ø (mm) |
2, 3, 6, 8 |
2, 3, 6, 8, 10 |
2, 3, 6, 8, 10, 12 |
2, 3, 6, 8, 10, 12 |
2, 3, 6, 8, 10, 12, 15 |
10, 15, 20, 22, 25 |
10, 15, 20, 22, 25 |
10, 15, 20, 22, 25 |
10, 15, 20, 25 |
Consump-tion (W) |
0.~150 |
0~250 |
0~500 |
0~650 |
0~950 |
0~1200 |
0~1500 |
0~1800 |
0~2000 |
Power Supply |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
Package Size (W*D*H) |
350*350 *550 mm (acoustic chamber). 465*300* 440mm (main body). |
350*350 *550 mm (acoustic chamber). 465*300* 440mm (main body). |
350*350 *550 mm (acoustic chamber). 465*300* 440mm (main body). |
350*350 *550 mm (acoustic chamber). 465*300* 440mm (main body). |
350*350 *550 mm (acoustic chamber). 465*300* 440mm (main body). |
350*350 *550 mm (acoustic chamber). 465*300* 440mm (main body). |
350*350 *550 mm (acoustic chamber). 465*300* 440mm (main body). |
350*350 *550 mm (acoustic chamber). 465*300* 440mm (main body). |
350*350 *550 mm (acoustic chamber). 465*300* 440mm (main body). |
Gross Weight |
30kg |
30kg |
30kg |
30kg |
30kg |
30kg |
30kg |
30kg |
30kg |
Technical Parameter for Amplitude Pole:
Size |
Ø2 |
Ø3 |
Ø6 |
Ø8 |
Ø10 |
Ø12 |
Ø15 |
Ø20 |
Ø22 |
Ø25 |
Ø28 |
Frequen-cy (KHz) |
20~25 |
20~25 |
20~25 |
20~25 |
20~25 |
20~25 |
20~25/ 19.5~20.5 |
19.5~20.5 |
19.5~20.5 |
19.5~20.5 |
19.5~20.5 |
Consumption (W) |
0~250 |
0~400 |
20~600 |
50~600 |
100~800 |
200~950 |
300~1000 |
400~1200 |
400~1200 |
800~1800 |
1000~2200 |
Crushing Capacity (ml) |
0.2~5 |
3~10 |
10~100 |
20~200 |
30~300 |
50~500 |
100~600 |
100~1000 |
200~1000 |
500~1200 |
500~2000 |
Continuous Flow Ultrasonic Cell Disruptor
Application:
It is suitable for the extraction of Chinese herbal medicine, cells, bacteria and emulsifying chemical nanometer material, suitable for small batch production or to provide accurate technical parameters for the future industrial production. Features:
|
Technical Parameters:
Model |
UCD-4000W-II |
Frequency |
20KHz |
Standard Amplitude-change Pole Ø |
40mm |
Optional Amplitude-change Pole Ø |
20mm, 25mm, 30mm, 38mm, 50mm, 60mm |
Crushing Capacity/once |
500mI~5L |
Crushing Capacity/Continuously |
100L/Day |
Max. Consumption |
4000W. Adjustable |
Time set |
Optional: Continuous/Pulse |
Max. Working Time |
99h59min59sec |
Safety System |
Automatic diagnosis; Overload. Over-temperature protection |
Standard Accessories |
Main machine, energy converter, standard amplitude, sound proof box (or supporting frame) |
Optional Accessories |
Low temperature water tank, stainless steel reactor, peristaltic pump |
Power Supply |
AC220V/110V±1 0%, 50/60Hz |
Package Size(W*D*H) |
640*305*450mm |
Gross Weight |
22kg |
Portable Ultrasonic Cell Disruptor
Technical Parameters:
Model |
UCD-PO1 |
Frequency (KHz) |
20~25, frequency automatic tracking |
Crushing Capacity(ml) |
3~10 (If choose Ø 3 ) 5-100 (If choose Ø 5 ) |
Standard Amplitude Pole Ø (mm) |
3 or 5 |
Generator Output Consumption(W) |
250 |
Ultrasonic Consumption(W) |
250 (can be adjusted according to customer's demand) |
Power Supply |
AC220V/110V±10%, 50/60Hz |
Package Size(W*D*H) |
465*300*440mm |
Gross Weight |
16kg |