Spectrophotometer
UV/VIS Spectrophotometer
Basic Functions:
Model |
Optical
System |
Wavelength Range |
Bandwidth |
Photo-metry |
QTY |
MULT |
KINS |
Scann-ing |
Bio |
BK-V1000 |
Single Beam |
325-1020nm |
4nm |
• |
|||||
BK-UV1000 |
Single Beam |
200-1020nm |
4nm |
• |
|||||
BK-V1200 |
Single Beam |
325-1020nm |
4nm |
• |
• |
||||
BK-UV1200 |
Single Beam |
200-1020nm |
4nm |
• |
• |
||||
BK-V1600 |
Single Beam |
320-1100nm |
4nm |
• |
• |
• |
• |
||
BK-UV1600 |
Single Beam |
190-1100nm |
4nm |
• |
• |
• |
• |
||
BK-V1800 |
Single Beam |
320-1100nm |
2nm |
• |
• |
• |
• |
||
BK-UV1800 |
Single Beam |
190-1100nm |
2nm |
• |
• |
• |
• |
||
BK-V1900 |
Single Beam |
190-1100nm |
2nm |
• |
• |
• |
• |
||
BK-UV1900 |
Single Beam |
190-1100nm |
2nm |
• |
• |
• |
• |
• |
• |
BK-S360 |
Single Beam |
190-1100nm |
1.8nm |
• |
• |
• |
• |
• |
• |
BK-S380 |
Single Beam |
190-1100nm |
1nm |
• |
• |
• |
• |
• |
• |
BK-S390 |
Single Beam |
190-1100nm |
0.5, 1, 2, 4,5nm |
• |
• |
• |
• |
• |
• |
BK-D560 |
Double Beam |
190-1100nm |
1.8nm |
• |
• |
• |
• |
• |
• |
BK-D580 |
Double Beam |
190-1100nm |
1nm |
• |
• |
• |
• |
• |
• |
BK-DS90 |
Double Beam |
190-1100nm |
0.5, 1, 2,4, 5nm |
• |
• |
• |
• |
• |
• |
UV/VIS Spectrophotometer
Features:
|
|
Technical Parameters:
Model |
BK-UV1000 |
BK-V1000 |
BK-UV1200 |
BK-V1200 |
Optical System |
Single Beam. Grating 1200 lines/mm |
Single Beam. Grating 1200 lines/mm |
Single Beam. Grating 1200 lines/mm |
Single Beam. Grating 1200 lines/mm |
Wavelength Range |
200~1020nm |
325~1000nm |
200~1O2Onm |
320~1O2Onm |
Spectral Bandwidth |
4nm |
4nm |
4nm |
4nm |
Wavelength Accuracy |
±2nm |
±2nm |
±2nm |
±2nm |
Wavelength Repeatability |
1nm |
1nm |
0 8nm |
0 8nm |
Photometric Accurancy |
±0.002A (0~0.5Abs), ±0.004 A (0.5~1.0Abs), ±0.5/%T (0~100% T) |
±0.002A (0~0.5Abs), ±0.004 A (0.5~1.0Abs), ±0.5/%T (0~100% T) |
±0.002A (0~0.5Abs), ±0.004 A (0.5~1.0Abs), ±0.5/%T (0~100% T) |
±0.002A (0~0.5Abs), ±0.004 A (0.5~1.0Abs), ±0.5/%T (0~100% T) |
Photometric Repatability |
0/001Abs (0~0 5Abs)/0.00/Abs(05~1:0Abs), ≤0.2%T(0 100%T) |
0/001Abs (0~0 5Abs)/0.00/Abs(05~1:0Abs), ≤0.2%T(0 100%T) |
0/001Abs (0~0 5Abs)/0.00/Abs(05~1:0Abs), ≤0.2%T(0 100%T) |
0/001Abs (0~0 5Abs)/0.00/Abs(05~1:0Abs), ≤0.2%T(0 100%T) |
Stray Light |
≤0.2% T @360nm; 220nm |
≤0.2% T @360nm; 220nm |
0.2% T @ 360nm, 220nm |
0.2% T @ 360nm, 220nm |
Stability |
±0 004A/h@500nm |
±0.002A/h@500nm |
±0.002A/h@500nm |
±0.002A/h@500nm |
Noise |
±0.001A |
±0.001A |
±0.001A |
±0.001A |
Display |
128*64 Dots LCD |
128*64 Dots LCD |
128*64 Dots LCD |
128*64 Dots LCD |
Photometric Mode |
T, A, C, E |
T, A, C, E |
T, A, C, E |
T, A, C, E |
Photometric Range |
0~200%T, -0.301~3.0A |
0~200%T, -0.301~3.0A |
0~200%T, -0.301~3.0A |
0~200%T, -0.301~3.0A |
Detector |
Silicon Photodiode |
Silicon Photodiode |
Silicon Photodiode |
Silicon Photodiode |
Light Source |
Deuterium Lamp, Tungsten Lamp |
Deuterium Lamp, Tungsten Lamp |
Deuterium Lamp, Tungsten Lamp |
Deuterium Lamp, Tungsten Lamp |
Input |
Membrane Keypad |
Membrane Keypad |
Membrane Keypad |
Membrane Keypad |
Standard Accessories |
10 mm glass cuvette*4 units 10mm quartz cuvette*2 units |
10mm glass cuvette*4 units |
10 mm glass cuvette*4 units 10mm quartz cuvette*2 units |
10mm glass cuvette*4 units |
Optional Accessories |
4-place Cell holder, Printer, Test tube holder, Deuterium lamp, Halogen lamp |
4-place Cell holder, Printer, Test tube holder, Deuterium lamp, Halogen lamp |
4-place Cell holder, Printer, Test tube holder, Deuterium lamp, Halogen lamp |
4-place Cell holder, Printer, Test tube holder, Deuterium lamp, Halogen lamp |
Power Supply |
110/220V±10%, 60/50Hz |
110/220V±10%, 60/50Hz |
110/220V±10%, 60/50Hz |
110/220V±10%, 60/50Hz |
Package Size (W*D*H)mm |
560*420*320 |
560*430*320 |
560*430*320 |
560*430*320 |
Gross Weight (kg) |
12 |
11.5 |
12 |
11.5 |
UV/VIS Spectrophotometer
Technical Parameters:
Model |
BK-UV1800 BK-UV1800PC |
BK-UVI600 BKUV1600PC |
BK-V1800 BK-V1800PC |
BK-V1600 BK-1600PC |
Optical System |
Single Beam, Grating 1200 Iines/mm |
Single Beam, Grating 1200 Iines/mm |
Single Beam, Grating 1200 Iines/mm |
Single Beam, Grating 1200 Iines/mm |
Wavelength Range |
190~1100nm |
190~1100nm |
320-1100nm |
320-1100nm |
Spectral Bandwidth |
2nm |
4nm |
2nm |
4nm |
Wavelength Accuracy |
±0.5nm |
±0.5nm |
±0.5nm |
±0.5nm |
Wavelength Repeatability |
≤0.3nm |
≤0.3nm |
≤0.3nm |
≤0.3nm |
Photometric Accuracy |
±0.002A (0~0.5Abs), 0.004A (0.5~1.0Abs), ±0.5% T (0~100% T) |
±0.002A (0~0.5Abs), 0.004A (0.5~1.0Abs), ±0.5% T (0~100% T) |
±0.002A (0~0.5Abs), 0.004A (0.5~1.0Abs), ±0.5% T (0~100% T) |
±0.002A (0~0.5Abs), 0.004A (0.5~1.0Abs), ±0.5% T (0~100% T) |
Photometric Repeatability |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.2 0/ T (0~100% T) |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.2 0/ T (0~100% T) |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.2 0/ T (0~100% T) |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.2 0/ T (0~100% T) |
Stray Light |
≤0.05% T @ 360nm; 220nmn |
≤0.05% T @ 360nm; 220nmn |
≤0.05% T @ 360nm; 220nmn |
≤0.05% T @ 360nm; 220nmn |
Stability |
±0.001A/h @ 500nm |
±0.001A/h @ 500nm |
±0.001A/h @ 500nm |
±0.001A/h @ 500nm |
Baseline Flatness |
±0.002A |
±0.002A |
±0.002A |
±0.002A |
Noise |
±0.0005A |
±0.0005A |
±0.0005A |
±0.0005A |
Display |
480*272 65 thousand true color TFT LCD |
480*272 65 thousand true color TFT LCD |
480*272 65 thousand true color TFT LCD |
480*272 65 thousand true color TFT LCD |
Photometric Mode |
T, A, C, E |
T, A, C, E |
T, A, C, E |
T, A, C, E |
Photometric Range |
0~200% T, -0.301~3.0A |
0~200% T, -0.301~3.0A |
0~200% T, -0.301~3.0A |
0~200% T, -0.301~3.0A |
Detector |
Silicon Photodiode |
Silicon Photodiode |
Silicon Photodiode |
Silicon Photodiode |
Light Source |
Deuterium Lamp, Tungsten Lamp |
Deuterium Lamp, Tungsten Lamp |
Deuterium Lamp, Tungsten Lamp |
Deuterium Lamp, Tungsten Lamp |
Input |
Membrane Keypad |
Membrane Keypad |
Membrane Keypad |
Membrane Keypad |
Output |
USB Print and data output, Connect PC |
USB Print and data output, Connect PC |
USB Print and data output, Connect PC |
USB Print and data output, Connect PC |
Standard Accessories |
10mm glass cuvette*4 units 10mm quartz cuvette*2 units |
10mm glass cuvette*4 units 10mm quartz cuvette*2 units |
10mm glass cuvette*4 units |
10mm glass cuvette*4 units |
Optional Accessories |
Single cell holder, General cell holder, Test tube holder, Solid sample holder, Deuterium lamp, Halogen lamp, 4-place Cell holder, Printer, Water-jacketed cell holder, Reflection accessory 5°, Auto 8-cell changer,. Micro cell holder, Water-jacketed cell holder, Constant-temperature system |
Single cell holder, General cell holder, Test tube holder, Solid sample holder, Deuterium lamp, Halogen lamp, 4-place Cell holder, Printer, Water-jacketed cell holder, Reflection accessory 5°, Auto 8-cell changer,. Micro cell holder, Water-jacketed cell holder, Constant-temperature system |
4-piace Cell holder, Pointer, Test tube holder, Deuterium lamp, Halogen Camp |
4-piace Cell holder, Pointer, Test tube holder, Deuterium lamp, Halogen Camp |
Power Supply |
AC110/220V±10%, 60/50Hz |
AC110/220V±10%, 60/50Hz |
AC110/220V±10%, 60/50Hz |
AC110/220V±10%, 60/50Hz |
Package Size (W*D*H)mm |
620*500*370 |
620*500*370 |
620*500*370 |
620*500*370 |
Gross Weight (kg) |
18 |
18 |
16.5 |
16.5 |
Scanning UV/VIS Spectrophotometer
Features:
|
Basic Functions:
a. Coefficient, Standard Sample input and Standard. Sample read three modes to establish standard curve. b. Establish A=K1*C+K0, can search original data, graph curve, parameters settings. c. Can save 240 group curves, can test 240 data in each curve. Double wavelength, Triple wavelength test functions.
|
Technical Parameters:
Model |
BK-UV1000 BK-UV1000PC |
BK-V1900 BK-V1900PC |
Optical System |
I Single Beam, Grating 1200 fines/mm |
I Single Beam, Grating 1200 fines/mm |
Wavelength Range |
190~11 00nm |
320-1100nm |
Spectral Bandwidth |
2nm |
2nm |
Wavelength Accuracy |
±0.5nm |
±0.5nm |
Wavelength Repeatability |
≤0 3nm |
≤0 3nm |
Photometric Accuracy |
±0.002A (0~0.5Abs), ±0.004A (0.5-1.0Abs), ±0.5% T (0-100% T) |
±0.002A (0~0.5Abs), ±0.004A (0.5-1.0Abs), ±0.5% T (0-100% T) |
Photometric Repeatability |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.2% T (0~100% T) |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.2% T (0~100% T) |
Stray Light |
≤0.05% T @ 360nM, 220nm |
≤0.05% T @ 360nM, 220nm |
Baseline Flatness |
±0.002A |
±0.002A |
Noise |
0.0005Abs @ 500nm |
0.0005Abs @ 500nm |
Display |
480*272 65 thousand true color TFT LCD |
480*272 65 thousand true color TFT LCD |
Photometric Mode |
T, A, C, E |
T, A, C, E |
Photometric Range |
0~200% T, -0.301~3.0A |
0~200% T, -0.301~3.0A |
Detector |
Silicon Photodiode |
Silicon Photodiode |
Light Source |
Deuterium Lamp, Tungsten Lamp |
Deuterium Lamp, Tungsten Lamp |
Input |
Membrane Keypad |
Membrane Keypad |
Output |
USB Print and data output, Connect PC |
USB Print and data output, Connect PC |
Standard Accessories |
10mm glass cuvette*4 units 10mm quartz cuvette*2 units |
10mm glass cuvette*4 units |
Stability |
±0.0008A/ h @500nm |
±0.0008A/ h @500nm |
Optional Accessories |
Single cell holder, General cell holder, Test tube holder, Solid sample holder, Deuterium lamp, Halogen lamp, 4-place Cell holder, Printer, Water-jacketed cell holder, Reflection accessory 5°, Auto 8-cell changer, Micro cell holder, Water-jacketed cell holder, Constant-temperature system |
Single cell holder, General cell holder, Test tube holder, Solid sample holder, Deuterium lamp, Halogen lamp, 4-place Cell holder, Printer, Water-jacketed cell holder, Reflection accessory 5°, Auto 8-cell changer, Micro cell holder, Water-jacketed cell holder, Constant-temperature system |
Power Supply |
AC110V/220±10%, 60/50Hz |
AC110V/220±10%, 60/50Hz |
Packages Size(W*D*H)mm |
620*500*370 |
620*500*370 |
Gross Weight(kg) |
18 |
16.5 |
Scanning UV/VIS Spectrophotometer
Basic Functions:
a Coefficient, Standard Sample input and Standard Sample read three modes to establish standard curve. b. Establish A=K1*C+K0, can search original data, graph 6 curve, parameters settings. c. Can save 240 group curves, can test 240 data in each curve. d. Double wavelength, Triple wavelength test functions |
Features:
|
Technical Parameters:
Model |
BK-S360 |
BK-S380 |
BK-S300 |
Optica System |
Single Beam. Grating 1200 lines/mm |
Single Beam. Grating 1200 lines/mm |
Single Beam. Grating 1200 lines/mm |
Wavelength Range |
190~1100nm |
190~1100nm |
190~1100nm |
Spectral Bandwidth |
1.8nm |
1nm |
0.5, 1, 2, 4, 5nm |
Wavelength Accuracy |
±0.3nm |
±0.3nm |
±0.3nm |
Wavelength Repeatability |
≤0.2nm |
≤0.2nm |
≤0.2nm |
Photometric Accuracy |
±0.002A (0~0.5Abs), ±0.004A (0.5-1.0Abs), ±0.3% T (0-100% T) |
±0.002A (0~0.5Abs), ±0.004A (0.5-1.0Abs), ±0.3% T (0-100% T) |
±0.002A (0~0.5Abs), ±0.004A (0.5-1.0Abs), ±0.3% T (0-100% T) |
Photometric Repeatability |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.1% T (0~100% T) |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.1% T (0~100% T) |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.1% T (0~100% T) |
Stray Light |
≤0.04% T @ 360nm, 220nm |
≤0.04% T @ 360nm, 220nm |
≤0.04% T @ 360nm, 220nm |
Stability |
±0.0001A/ h @500nm |
±0.0001A/ h @500nm |
±0.0001A/ h @500nm |
Baseline Flatness |
±0.0015A |
±0.0015A |
±0.0015A |
Noise |
0.0004Abs @ 500nm |
0.0004Abs @ 500nm |
0.0004Abs @ 500nm |
Display |
65 thousand true color TFT LCD (480*800) |
65 thousand true color TFT LCD (480*800) |
65 thousand true color TFT LCD (480*800) |
Photometric Mode |
T, A, C, E |
T, A, C, E |
T, A, C, E |
Photometric Range |
0~200% T, -0.301~3.0A |
0~200% T, -0.301~3.0A |
0~200% T, -0.301~3.0A |
Detector |
Silicon Photodiode |
Silicon Photodiode |
Silicon Photodiode |
Light Source |
Deuterium Lamp, Tungsten Lamp |
Deuterium Lamp, Tungsten Lamp |
Deuterium Lamp, Tungsten Lamp |
Input |
Membrane Keypad |
Membrane Keypad |
Membrane Keypad |
Output |
USB Print and data output, Connect PC |
USB Print and data output, Connect PC |
USB Print and data output, Connect PC |
Standard Accessories |
10mm glass cuvette*4 units 10mm quartzcuvette*2 units software |
10mm glass cuvette*4 units 10mm quartzcuvette*2 units software |
10mm glass cuvette*4 units 10mm quartzcuvette*2 units software |
Optional Accessories |
Single cell holder, General cell holder, Test tube holder, Solid sample holder, Deuterium lamp, Halogen lamp, 4-place Cell holder, Printer, Water-jacketed cell holder, Reflection accessory 5°, Auto 8-cell changer, Micro cell holder, Water-jacketed cell holder, Constant-temperature system |
Single cell holder, General cell holder, Test tube holder, Solid sample holder, Deuterium lamp, Halogen lamp, 4-place Cell holder, Printer, Water-jacketed cell holder, Reflection accessory 5°, Auto 8-cell changer, Micro cell holder, Water-jacketed cell holder, Constant-temperature system |
Single cell holder, General cell holder, Test tube holder, Solid sample holder, Deuterium lamp, Halogen lamp, 4-place Cell holder, Printer, Water-jacketed cell holder, Reflection accessory 5°, Auto 8-cell changer, Micro cell holder, Water-jacketed cell holder, Constant-temperature system |
Power Supply |
AC110/220±10%, 60/50Hz |
AC110/220±10%, 60/50H |
AC110/220±10%, 60/50Hz |
Package Size (W*D*H) mm |
740*570*440 |
740*570*440 |
740*570*440 |
Gross Weight(kg) |
25 |
25 |
25 |
Double Beam Scanning UV/VIS Spectrophotometer
Features:
|
Basic Functions:
Quantitative Linear fit and Linear fit through zero two modes a Coefficient, Standard Sample input and Standard Sample read three modes to establish standard curve. a. Establish A=K1*C+K0, can search origina1 data, graph curve, parameters setting b. Can save 240 group curves, can test 240 data in each curve. c. Double wavelength, Triple wavelength test functions.
derivation, arithmetical operations to the graph.
and Biuret. |
Technical Parameters:
Model |
BK-D560 |
BK-D580 |
BK-D590 |
Optical System |
Double Beam. Grating 1200 lines/mm |
Double Beam. Grating 1200 lines/mm |
Double Beam. Grating 1200 lines/mm |
Wavelength Range |
190 ~1100nm |
190 ~1100nm |
190 ~1100nm |
Spectral Bandwidth |
1.8nm |
1nm |
0.5, 1, 2, 4, 5nm |
Wavelength Accuracy |
±0.3nm |
±0.3nm |
±0.3nm |
Wavelength Repeatability |
≤0.2nm |
≤0.2nm |
≤0.2nm |
Photometric Accuracy |
±0.002A (0~0.5Abs), ±0.004A (0.5~1.0Abs), ±0.3% T (0-100% T) |
±0.002A (0~0.5Abs), ±0.004A (0.5~1.0Abs), ±0.3% T (0-100% T) |
±0.002A (0~0.5Abs), ±0.004A (0.5~1.0Abs), ±0.3% T (0-100% T) |
Photometric Repeatability |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.2% T (0~100% T) |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.2% T (0~100% T) |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤0.2% T (0~100% T) |
Stray Light |
≤0.04% T @ 360nm, 220nm |
≤0.04% T @ 360nm, 220nm |
≤0.04% T @ 360nm, 220nm |
Stability |
±0.0003A/ h @500nm |
±0.0003A/ h @500nm |
±0.0003A/ h @500nm |
Baseline Flatness |
±0.0005A |
±0.0005A |
±0.0005A |
Noise |
0.0002Abs |
0.0002Abs |
0.0002Abs |
Display |
65 thousand true color TFT LCD (480*800) |
65 thousand true color TFT LCD (480*800) |
65 thousand true color TFT LCD (480*800) |
Photometric Mode |
T, A, C, E |
T, A, C, E |
T, A, C, E |
Photometric Range |
0~200% T, -0.301~3.0A |
0~200% T, -0.301~3.0A |
0~200% T, -0.301~3.0A |
Detector |
Silicon Photodiode |
Silicon Photodiode |
Silicon Photodiode |
Light Source |
Deuterium Lamp, Tungsten Lamp |
Deuterium Lamp, Tungsten Lamp |
Deuterium Lamp, Tungsten Lamp |
Input |
Membrane Keypad |
Membrane Keypad |
Membrane Keypad |
Output |
USB Print and data output, Connect PC |
USB Print and data output, Connect PC |
USB Print and data output, Connect PC |
Standard Accessories |
10mm glass cuvette*4 units 10mm quartzcuvette*2 units software |
10mm glass cuvette*4 units 10mm quartzcuvette*2 units software |
10mm glass cuvette*4 units 10mm quartzcuvette*2 units software |
Optional Accessories |
Single cell holder, General cell holder, Test tube holder, Solid sample holder, Deuterium lamp, Halogen lamp, 4-place Cell holder, Printer, Water-jacketed cell holder, Reflection accessory 5°, Auto 8-cell changer, Micro cell holder, Water-jacketed cell holder, Constant-temperature system |
Single cell holder, General cell holder, Test tube holder, Solid sample holder, Deuterium lamp, Halogen lamp, 4-place Cell holder, Printer, Water-jacketed cell holder, Reflection accessory 5°, Auto 8-cell changer, Micro cell holder, Water-jacketed cell holder, Constant-temperature system |
Single cell holder, General cell holder, Test tube holder, Solid sample holder, Deuterium lamp, Halogen lamp, 4-place Cell holder, Printer, Water-jacketed cell holder, Reflection accessory 5°, Auto 8-cell changer, Micro cell holder, Water-jacketed cell holder, Constant-temperature system |
Power Supply |
AC110/220±10%, 60/50Hz |
AC110/220±10%, 60/50Hz |
AC110/220±10%, 60/50Hz |
Package Size (W*D*H) mm |
740*570*440 |
740*570*440 |
740*570*440 |
Gross Weight(kg) |
25 |
25 |
25 |
UV/VIS Spectrophotometer Accessories
Standard Type Quartz Cuvette
Technical Parameters:
Model |
Path Length(mm) |
External Size (W*D*H) mm |
Volume(ml) |
No. of LID |
No. of Stoppers |
S/Q/I |
1 |
12.5*3.5*45 |
0.4 |
1 |
/ |
S/Q/2 |
2 |
12.5*4.5*45 |
0.7 |
1 |
/ |
S/Q/5 |
5 |
12.5*7.5*45 |
1.7 |
1 |
/ |
S/Q/10 |
10 |
12.5*12.5*45 |
3.5 |
1 |
/ |
S/Q/20 |
20 |
12.5*22.5*45 |
7.0 |
1 |
/ |
S/Q/40 |
40 |
12.5*42.5*45 |
14.0 |
1 |
/ |
S/Q/50 |
50 |
12.5*52.5*45 |
17.5 |
1 |
/ |
S/Q/100 |
100 |
12.5*102.5*45 |
35.0 |
1 |
/ |
SS/Q/I |
1 |
12.5*3.5*48 |
0.4 |
/ |
1 |
SS/0/2 |
2 |
12.5*4.5*48 |
0.7 |
/ |
1 |
SS/Q/5 |
5 |
12.5*7.5*48 |
1.7 |
/ |
1 |
SS/Q/10 |
10 |
12.5*12.5*48 |
3.5 |
/ |
Value |
SS/Q/20 |
20 |
12.5*22.5*48 |
7.0 |
/ |
1 |
SS/Q/40 |
40 |
12.5*42.5*48 |
14.0 |
/ |
1 |
SS/Q/50 |
50 |
12.5*52.5*48 |
17.5 |
/ |
1 |
SS/Q/100 |
100 |
12.5*102.5*48 |
35.0 |
/ |
1 |
Flame Spectrophotometer
It is an analytical instrument based on emission spectrum principle, using the thermal energy of flame to make the certain element motivate luminescence to analyze the content of certain element in the material, widely used in the analysis and determination of agricultural fertilizer, soil, cement, ceramics and silicate industry and pathological studies of health care etc.
Technical Parameters:
Model |
BK-FP840 |
BK-FP6410 |
BK-FP6430 |
BK-FP6431 |
BK-FP6440 |
BK-FP6450 |
|
Sensitivity |
K |
0.01ppm |
0.01ppm |
0.01ppm |
0.01ppm |
0.01ppm |
0.01ppm |
Na |
0.01ppm |
0.01ppm |
0.01ppm |
0.01ppm |
0.01ppm |
0.01ppm |
|
Li |
/ |
/ |
0.01ppm |
/ |
0.1ppm |
0.1ppm |
|
Ca |
/ |
/ |
/ |
2ppm |
2ppm |
2ppm |
|
Ba |
/ |
/ |
/ |
/ |
/ |
6ppm |
|
Range |
K |
0~100ppm |
0~100ppm |
0~100ppm |
0~100ppm |
0~100ppm |
0~100ppm |
Na |
0~160ppm |
0~160ppm |
0~160ppm |
0~160ppm |
0~160ppm |
0~160ppm |
|
Li |
/ |
/ |
0~100ppm |
/ |
0~100ppm |
0~100ppm |
|
Ca |
/ |
/ |
/ |
0~1000ppm |
0~1000ppm |
0~1000ppm |
|
Ba |
/ |
/ |
/ |
/ |
Valu |
0-3000ppm |
|
Linearity |
K |
0.195ppm (0.39~3.12) ppm |
0.195ppm (0.39~3.12) ppm |
0.195ppm (0.39~3.12)ppm |
0.195ppm (0.39~3.12) ppm |
0.195ppm (0.39~3.12) ppm |
0.195ppm (0.39~3.12)ppm |
Na |
0.69ppm (1.15~9.2) ppm |
0.69ppm (1.15~9.2) ppm |
0.69ppm (1.15~9.2) ppm |
0.69ppm (1.15~9.2) ppm |
0.69ppm (1.15~9.2) ppm |
0.69ppm (1.15~9.2) ppm |
|
Li |
/ |
/ |
0.l5ppm (0.26~5)ppm |
/ |
0.15ppm (0.25~5)ppm |
0.15ppm (0.25~5)ppm |
|
Ca |
/ |
/ |
/ |
3ppm (5~100)ppm |
3ppm (5~100)ppm |
3ppm (5~100)ppm |
|
Ba |
/ |
/ |
/ |
/ |
/ |
9ppm |
|
Linearity Error |
K |
≤0.195ppm |
≤0.195ppm |
≤0.195ppm |
≤0.195ppm |
≤0.195ppm |
≤0.195ppm |
Na |
≤0.69ppm |
≤0.69ppm |
≤0.69ppm |
≤0.69ppm |
≤0.69ppm |
≤0.69ppm |
|
Li |
/ |
/ |
≤0.147ppm |
/ |
≤0.147ppm |
≤0.147ppm |
|
Ca |
/ |
/ |
/ |
≤3ppm |
≤3ppm |
≤3ppm |
|
Ba |
/ |
/ |
/ |
/ |
/ |
≤9.042ppm |
|
MDL |
K |
≤0.156ppm |
≤0.156ppm |
≤0.156ppm |
≤0.156ppm |
≤0.156ppm |
≤0.156ppm |
Na |
≤0.184ppm |
≤0.184ppm |
≤0.184ppm |
≤0.184ppm |
≤0.184ppm |
≤0.184ppm |
|
Li |
/ |
/ |
≤0.105ppm |
/ |
≤0.105ppm |
≤0.105ppm |
|
|
Ca |
/ |
/ |
/ |
≤2ppm |
≤2ppm |
≤2ppm |
Ba |
/ |
/ |
/ |
≤60.28ppm |
/ |
≤60.28ppm |
|
Repeatability |
1% CV for 20 consecutive samples |
1% CV for 20 consecutive samples |
1% CV for 20 consecutive samples |
1% CV for 20 consecutive samples |
1% CV for 20 consecutive samples |
1% CV for 20 consecutive samples |
|
Response Time |
<8s |
<8s |
<8s |
<8s |
<8s |
<8s |
|
Sample Uptake |
<6ml/min |
<6ml/min |
<6ml/min |
<6ml/min |
<6ml/min |
<6ml/min |
|
Ambient Temp |
10°C~35°C |
10°C~35°C |
10°C~35°C |
10°C~35°C |
10°C~35°C |
10°C~35°C |
|
Humidity |
≤85% |
≤85% |
≤85% |
≤85% |
≤85% |
≤85% |
|
Power Supply |
AC110/220V±10%, 60/50Hz |
AC110/220V ±10%, 60/50Hz |
AC110/220V ±10%, 60/50Hz |
AC110/220V ±10%, 60/50Hz |
AC110/220V ±10%, 60/50Hz |
AC110/220V ±10%, 60/50Hz |
|
Consump-tion |
250W |
250W |
250W |
250W |
250W |
250W |
|
Standard Accessory |
Air compressor |
Air compressor |
Air compressor |
Air compressor |
Air compressor |
Air compressor |
|
Package Size |
770*560*390mm |
770*560*390mm |
770*560*390mm |
770*560*390mm |
770*560*390mm |
770*560*390 |
|
Gross weight |
22kg |
22kg |
22kg |
22kg |
22kg |
22kg |
Fluorescence Spectrophotometer
Applications:
Fluorescence analysis can provide information including excitation and emission spectrum, emission light intensity and measurement of life of emission light and polarization fluorescence etc. and a wide lineal range of working curve.
Fluorescence analysis can provide information including excitation and emission spectrum, emission light intensity and measurement of life of emission light and polarization fluorescence etc. and a wide lineal range of working curve.
This method has been used in: Medical science and clinical, Pharmaceutical science and pharmacology, Biochemistry, Food industry, Pollution and Organic, and inorganic chemistry.
Features for BK-F96PRO:
Features for BK-F93:
|
Technical Parameters:
Model |
BE-F96PRO |
BK-F93 |
Light Source |
Hamamatsu 150W Xenon lamp |
4 digits LED |
Excitation Filter |
Interference optical filter a) Standard set is equipped with an interference optical filter of central wavelength at 365nm and 10nm bandwidth b) An optional interference optical filer of 25mm diameter of wavelength of 250~700nm can be provided on users demand. |
LED options a) Standard set includes LED at wavelength 365nm b) The A set includes LED wavelength at 365nm, 376nm, 392nm, 405nm c) Customizable wavelength from 360nm to 600nm |
Emission Monochromator |
C-T diffraction grating (Em 200~900nm, bandwidth 10nm) |
360~650nm (C-T diffraction grating) |
Wavelength Accuracy |
±1nm |
±2nm |
Wavelength Repeatability |
≤0.5nm |
≤1nm |
Sensitivity |
Raman peak of water in 1 cm quartz fluorescence cuvette with S/N≥150 |
1*10-9/ml (Standard aqua of the sulfuric acid Quinine, 12nm bandwidth) |
Linear Measurement(r) |
≥0.995 |
≥0.995 |
Stability |
better than 1.5%10min |
better than 3%/10min |
Response Time |
(0.1~4)s, 6 stages adjustable |
(0.1~4)s |
Fluorescence Display Value |
0.00~600.00 |
0.00~250.00 |
Standard Accessories |
365nm filter (Preassembled), 1 pc F96PRO software package, 1 pc USB interface, 1 pc Quartz fluorescence sample cell 10mm, 1 pair |
RS232 serial port, Glass fluorescence cuvette 10mm 1 pair |
Optional Accessories |
Fuses(2A/5A), 200-700nm interference optical filter (Ҩ25mm) Quartz fluorescence sample ceII10mm Multi-function fluorescent sample rack holder, Membrane sample rack, Powder sample rack, Sample cell jacket, Octave Filters 200uL microcentrifuge tube accessory Up conversion fluorescent accessory |
Data processing software package (pack, for PC) Fuses(2A) Quartz fluorescence cuvette 10mm Optional LED A Set includes: 365nm, 376nm, 392nm, 405nm |
Power Supply |
AC110/220V±10%, 60/50Hz |
AC110/220V±10%, 60/50Hz |
Package Size (W*D*H)mm |
450*420*310 |
380*420*240 |
Gross Weight (kg) |
14 |
9 |
BK-AA4530F Atomic Absorption Spectrophotometer
Standard Accessories:
|
Features:
|
Technical Parameters:
Model |
BK-AA4530F |
Wavelength Range |
190~900nm |
Spectral Bandwidth |
O.1, 0.2, 0.4, 1.0 and 2.0nm |
Wavelength Accuracy |
≤±0.15nm |
Wavelength Receptivity |
≤0.04nm |
Base Line Stability |
≤0.002A/30min (Cu) |
Characteristic Concentration |
0.02pg/ml/1% (Cu) |
Detection Limit |
0.004pg/ml (Cu) |
Measurement Repeatability |
≤0.05% |
Grating |
1800 lines/mm |
Inflamer |
All-metal titanium burner |
All-metal titanium burner |
Efficient glass atomizer |
D2 Background Calibration |
When the background is 1 A, the background ability should be deducted not lessthan 50 times; self-absorption background deduction method |
Power Supply |
220V, 50Hz |
Packing Size(W*D*H) mm |
850*700*750 (Main instrument); 950*620*1020 (Accessories) |
Gross Weight(kg) |
105 (Main instrument); 100 (Accessories) |
Standar Accessories: |
PC workstation; HP inkjet printer; Oil free Air compressor; Acetylene reducing valve; Cu Hollow cathode lamp; Air filter |
Optional Accessories |
Graphite Furnace 451OGF; Hollow cathode lamp (Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc.) |
Lamp |
8 |
Flame System:
Acetylene Air Burner |
100 |
Ignition Dynamic Baseline Drift |
≤0.006A/30min |
Characteristic Concentration |
≤0.025µg/ml/1%(Cu) |
Related Standard Deviation of the Accuracy |
≤0.5%(Cu, absorbance 0.8A) (detection limit Cus≤0.008µg/ml) |
Safety System |
Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner. |
Graphite Furnace (Optional):
Max. Temperature |
3000°C |
Max Heating Speed |
≥2000°C/S |
Characteristic Quantity |
Cd≤0.5*3%-12g Cu≤5*10-11g |
Accuracy |
Cu≤3% Cd≤3% |
Safety System |
Over current protection Low air pressure alrm/protection Low cooling water flow alarm/protection |
Power Supply |
220V, 50Hz |
Comsumption |
7000W |
Packing Size(W*D*H)mm |
740*640*700 |
Gross Weight(kg) |
90 |
BK-AA320N Atomic Absorption Spectrophotometer
Features:
- Built-in computer data processing and LC0 display.
- Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift.
- Quickly: The cathode lamp does not need to be pre-heated for long time and sample can be analyzed immediately.
- High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test an low charactheristic concentration.
- High energy optical path.
- Long-life and anti-corrosive atomization system.
- Multi-functional analysis mode: Flame Absorption, Flame Emission, Graphite Furnace Atomic Absorption, Hydrade Generation.
- Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame and extend the analytic elements to reach more than 60.
Technical Parameters:
Model |
BK-AA320N |
Wavelength Range |
190~900nm |
Wavelength Accuracy |
≤±0.5nm |
Wavelength Repeatability |
≤0.3nm (single direction) |
Spectral Bandwidth |
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm |
Grating |
1800 lines/mm |
Resolution |
≤40% |
Base Line Stability |
±0.004Abs/30min |
Characteristic Concentration |
≤0.04µg/ml/1% (Cu) |
Detection Limit |
≤0.008µg/ml (Cu) |
Background Calibration |
>30 times |
Power Supply |
220V, 50Hz |
Package Size(W*D*H) |
1250*795*765mm (Main Instrument), 545*445*1385mm (Accessories) |
Gross Weight |
138kg (Main instrument), 56kg (Accessories) |
Standard Accessories |
RS232 serial port, Oil-free air compressor, Glass Atom1zer, Cu Hollow cathode lamp, Atomizer unit Burner unit Dust cover, Water-separating gas filter, Titanium burner-10cm |
Optional Accessories |
Software, Model GA3202 HGA graphite furnace system, Hydride generator, Graphite tubes, Recirculating cooling water system, Hollow cathode lamp (Ag, Au, Ca, Cd, Cr ,Fe, Hg ,K ,Mg ,Mn, Na, N!, Pb, Zn, AS, etc) |
NIR Spectrophotometer
NIR spectrophotometer, mainly used for liquid samples qualitative and quantitative analysis, applies to gasoline, drinks, milk and other areas of nutrients, water chemistry and other physical properties of the rapid non-destructive analysis determination.
The instrument monitors the ambient temperature and humidity in real time and stores it in the spectrum file, which is convenient for users to check and optimize the measurement conditions. Features:
|
Technical Parameters:
Model |
BK-S430 |
Optical system |
Grating monochromator |
Wavelength Scanning Interval |
8nm |
Wavelength Range |
900~2500nm |
Wavelength Accuracy |
≤0.2nm |
Wavelength Reproducibility |
≤0.05 nm |
Stray Light |
≤0.1% |
Scanning Time |
1 minute or adjustable |
Noise |
≤0.0005 Abs |
Interface |
USB |
Standard Accessories |
2*1cm quartz square sample cell , 2*1mm quartz micro sample cell |
Optional Accessories |
Laptop |
Power Supply |
110V/220±10%, 60/50Hz |
Packing size |
360*460*240mm |
Gross Weight |
12kg |