Homogenizer
Typical Samples:
Features:
|
Technical Parameters:
Model |
HG-24 |
Speed Range |
4.0 m/s~7.0 m/s (in steps of 0.05 m/s) |
Cycle Duration |
1~90 s (in step of 1 s) |
Pause Time |
1~90 s (in step of 1 s) |
Acceleration |
< 4s |
Programmable |
50 |
Number of Cycles |
10 |
Display |
OLED |
Number of Samples |
24*2mI / 1.5mI or 12*5mI |
Tube Type |
Grinding tube |
Running Noise |
< 70dB |
Power Supply |
AC110/220V±10%, 50/60Hz |
External Size (L*D*H) |
280*360*385mm |
Package Size (L*D*H) |
620*520*630mm |
Net/Gross Weight |
25kg/37kg |
Semi-Automated Plate Sealer
Features:
Control: The PS-2 Semi Automated Plate Sealer allows optimal settings tor all types of plates and sealing material. Sealing time and temperature can be set using the control knob.
|
Technical Parameters:
Model |
PS-2 |
Adjustable Sealing Temperature |
80~200°C |
Temperature Accurate |
1.0°C |
Seal Time |
0.5s~10s, increased by 0 1 sec |
Seals Plate Heights |
9 to 48mm |
Compatible Plate Materials |
PP(Polypropylene), PS(Polystyrene), PE(Polyethylene) |
Compatible Plate Types |
SBS standard plates, Deep-well plates, PCR plates (Skirted, semi-skirted and no-skirted formats) |
Consumption |
300W |
Power Supply |
AC110/220V±10%, 50/60Hz |
External Size (L*D*H) |
370*178*330mm |
Package Size (L*D*H) |
530*320*540mm |
Net/Gross Weight |
9.6kg/12kg |
Denaturation & Hybridization System
Features:
|
Technical Parameters:
Model |
HS-500 |
Temperature Control Range |
RT+5°C~99.9°C |
Capacity |
12 Slides |
Temperature Accuracy |
±1°C |
Temperature Uniformity |
±1°C |
Timing Range |
1min~99h59min or 1sec~99min59sec |
Heating Time (37°Cto 95°C) |
≤3min |
Cooling Time (95°Cto 45°C) |
≤7min |
Temperature Range |
30°C~100°C |
Power Supply |
AC110/220V±10%, 50/60Hz |
External Size (L*W*H) mm |
225*420*143 |
Package Size (L*W*H) mm |
550*360*290 |
Net Weight |
5.8kg |
Gross Weight |
9.8kg |
Thermo Shaker Incubator
Technical Parameters:
Model |
TSI-100 |
Temperature Control Range |
0°C~100°C (if Ambient Temp ≤20°C) 4°C~100°C (if Ambient Temp ≤25°C) 10°C~100°C (if Ambient Temp ≤30°C) |
Timing Range |
1 min~99h59min |
Mixing Speed |
200rpm~1500rpm |
Mixing Orbit |
2mm |
Temperature Control Accuracy |
±0.5 °C |
Display Accuracy |
0.1°C |
Heating Time |
<15min |
Cooling Time |
≤30min (RT~RT-20 °C) ≤5min (100 °C~20 °C) |
Cooling & Heating Parts |
Peltier |
Power Supply |
AC110/220V±10%, 50/60Hz |
External Size (L*W*H) |
300*220*175mm |
Package Size (L*W*H) |
470*370*330mm |
Net Weight |
8.7kg |
Gross Weight |
11.5kg |
Technical Parameter:
Model |
MS-4 |
Speed |
200~1500 rpm/min (Standard) 200~1000 rpm/min (Deep well plate or tube holder) |
Orbit |
3mm |
Timer |
1min~99h59min |
Consumption |
40W |
Power Supply |
AC110/220V±10%, 50/60Hz |
External Size (L*D*H) |
290*270*120mm |
Package Size (L*D*H) |
470*370*330mm |
Net Weight |
7kg |
Gross Weight |
9kg |
Dry Bath Incubator
Features:
- Exceptional temperature uniformity and accuracy - due to advanced temperature control combined with high quality, precision engineered block providing excellent thermal contact.
- Wide range of interchangeable aluminum blocks.
- Heat to 105°C, optional external temperature probe.
- Blocks optional available as accessories for all applications - tubes, vials, and microplates.
- Block extraction tool is supplied, allowing blocks to be removed easily.
1. Specification for DBI-I Dry Bath Incubator:
|
2. Specification for DBI-II Dry Bath Incubator:
|
3. Specification for Dry Bath Incubator DBI-III:
|
4. Specification for Dry Bath Incubator DBI-IV:
|
5. Specification for DBI-V Dry Bath Incubator:
|
6. Specification for DBI-VI Dry Bath Incubator:
|
Gel Card Incubator
Applications:
Gel card incubator is matched with our gel cards centrifuge to use and holds 2 independent incubation zones with a capacity for 12 gel cards. It can be suitable for many types of gel cards from different manufacturers. Features:
|
Technical Parameters:
Model |
BK-GCI24 |
Capacity |
24 cards |
Temperature |
37°C |
Temperature Accuracy |
<0.5°C |
Temperature Uniformity |
±0.5°C |
Time Range |
0~99min59s |
Consumption |
250W |
Power Supply |
AC110/220V±10%, 50/60Hz |
External Size (W*D*H)mm |
280*390*140 |
Package Size (W*D*H)mm |
445*335*190 |
Net/Gross Weight(kg) |
6.2 / 8 |
Gel Card Centrifuge
Application:
Gel card centrifuge is used in blood serology, blood type routine test, erythrocyte washing, microcolumn agglutination, immunology, and other tests. Features:
|
Technical Parameters:
Model |
BKC-GC12 |
BKC-GC24 |
Max. Speed |
3000rpm |
3000rpm |
Max. RCF |
830xg |
1080xg |
Rotor |
12 cards |
24 cards |
Speed Precision |
±20rpm |
±20rpm |
Time Range |
0~99min |
0~99min |
Noise |
≤55dB |
≤55dB |
Power Supply |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
External Size(W*D*H)mm |
483*320*265 |
528*370*280 |
Package Size(W*D*H)mm |
560*380*330 |
610*435*340 |
Gross Weight(kg) |
24 |
30 |
Sample Concentration (Nitrogen Evaporator)
Technical Parameters:
Model |
SC-I |
SC-II |
Temp. Range |
RT+5~150°C |
RT+5~150°C |
Low Nitrogen Consumption |
330mI/min/sample |
330mI/min/sample |
Time Required from 40°C to 150°C |
≤30 minutes |
≤30 minutes |
Needles Length |
150mm |
150mm |
Temp. Control Discrepancy |
±0.1°C |
±0.1°C |
Consumption |
200W |
400W |
Power Supply |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
External Size (L*D*H) |
280*240*500mm |
280*240*500mm |
Package Size (L*D*H) |
490*390*360mm |
490*390*360mm |
N/G Weight |
7/11kg |
7/11kg |