TRIVANCED PTE. LTD. - Laboratory, Semiconductor and Medical Equipment Supplies and Accessories in Singapore - Furnace, Oven, Chamber, Freezer, Refrigerator, Incubator, Sterilizer, Sterilization, Dehumidifier, Vacuum

  • Home
  • About
  • Products
  • Services
  • Contact
  • Home
  • About
  • Products
  • Services
  • Contact

Pre-Processing of Bio-Samples

Homogenizer

Picture
Picture
Typical Samples:
  • Soil and sediments
  • Human, animal, plant cells        
  • Swabs and feces
  • Microorganisms                      
  • Drugs, polymers, lotions, etc.

Features:
 
  • "3D Rotating High Speed Motion" for quick disruption of those fibrous tissues and resistant cells.
  • 50 Programmable memory settings and user optional condition settings.
  • A wide range of rotation speed settings from 4.0m/s to 7.0m/s, increment 0.05m/s.
  •  Brushless motor realizing no brush particle generation and no brush replacement.
  • Easy to remove sample tube holder and easy to fix sample tubes with the turn of the central knob.
  • Easy to monitor the disruption process through the clear lid.
  • Disposable tubes ensure no threat of cross-contamination.
  • Most samples can be processed in 35 seconds or less.

Technical Parameters:
Model
HG-24
Speed Range
4.0 m/s~7.0 m/s (in steps of 0.05 m/s)
​Cycle Duration
1~90 s (in step of 1 s)
Pause Time
1~90 s (in step of 1 s)
​Acceleration
​< 4s
Programmable
​50
​Number of Cycles
10
Display
​OLED
​Number of Samples
24*2mI / 1.5mI or 12*5mI
​Tube Type
​Grinding tube
Running Noise
< 70dB
​Power Supply
AC110/220V±10%, 50/60Hz
​External Size (L*D*H)
​280*360*385mm
Package Size (L*D*H)
620*520*630mm
​Net/Gross Weight
​25kg/37kg

Semi-Automated Plate Sealer

Picture
Picture
Features:
  • Format different micro well plates and heat seals
  • Adjustable Sealing Temperature: 80 -200°C
  • OLED display screen, high light, and no visual angle limit
  • Plate adapters allow use of PCR plate or visually any ANSI micro plate.
  • Sealing time and temperature can be set by using the control knob.
  • OLED display screen, high light, and no visual angle limit.

Control:
The PS-2 Semi Automated Plate Sealer allows optimal settings tor all types of plates and sealing material. Sealing time and temperature can be set using the control knob.
  • Automatic Counting Function
  • Sealing Time in 0.1 sec increments
  • Sealing Temperature in 1.0°C increments
Picture
Technical Parameters:
Model
​PS-2
​Adjustable Sealing Temperature
80~200°C
Temperature Accurate
​1.0°C
​Seal Time
0.5s~10s, increased by 0 1 sec
Seals Plate Heights
​9 to 48mm
Compatible Plate Materials
PP(Polypropylene), PS(Polystyrene), PE(Polyethylene)
Compatible Plate Types
SBS standard plates, Deep-well plates, PCR plates (Skirted, semi-skirted and no-skirted formats)
​Consumption
300W
Power Supply
​AC110/220V±10%, 50/60Hz
External Size (L*D*H)
​370*178*330mm
Package Size (L*D*H)
​530*320*540mm
​Net/Gross Weight
​9.6kg/12kg

Denaturation & Hybridization System

Picture
Picture
Features: 
  • Touch screen easy to read, program and use
  • It can run In-situ PCR experiments
  • Possibility to export cycle data via USB memory
  • Four operation modes: denaturation/hybridization, hybridization fixed temperature, custom, In-situ PCR
  • Can be used as a fixed temperature slide warmer
  • Rapid temperature warm-up and accuracy of ±1°C
  • Superior temperature uniformity across all slide positions
  • Perfect humidity control system
Technical Parameters:
Model
HS-500
Temperature Control Range
RT+5°C~99.9°C
​Capacity
12 Slides
Temperature Accuracy
​±1°C
Temperature Uniformity
±1°C
Timing Range
1min~99h59min or 1sec~99min59sec
Heating Time (37°Cto 95°C)
≤3min
Cooling Time (95°Cto 45°C)
≤7min
​Temperature Range
​30°C~100°C
Power Supply
AC110/220V±10%, 50/60Hz
​External Size (L*W*H) mm 
225*420*143
Package Size (L*W*H) mm
550*360*290
​Net Weight
5.8kg
​Gross Weight
​9.8kg

Thermo Shaker Incubator​​

Picture
Technical Parameters:
Model
TSI-100
Temperature Control Range
0°C~100°C (if Ambient Temp ≤20°C)
4°C~100°C (if Ambient Temp ≤25°C)
10°C~100°C (if Ambient Temp ≤30°C)
​Timing Range
1 min~99h59min
Mixing Speed
200rpm~1500rpm
​Mixing Orbit
​2mm
Temperature Control Accuracy
±0.5 °C
​Display Accuracy
0.1°C
Heating Time
​<15min
​Cooling Time
​≤30min (RT~RT-20 °C)
≤5min (100 °C~20 °C)
Cooling & Heating Parts
Peltier
Power Supply
​AC110/220V±10%, 50/60Hz
External Size (L*W*H)
​300*220*175mm
Package Size (L*W*H)
470*370*330mm
Net Weight
8.7kg
Gross Weight
​11.5kg
Technical Parameter:
Model
​MS-4
Speed
200~1500 rpm/min (Standard) 200~1000 rpm/min (Deep well plate or tube holder)
​Orbit
3mm
​Timer
1min~99h59min
Consumption
​40W 
​Power Supply
AC110/220V±10%, 50/60Hz
External Size (L*D*H)
​290*270*120mm
​Package Size ​(L*D*H)
470*370*330mm
​Net Weight
7kg
​Gross Weight
​9kg

Dry Bath Incubator

Features: 
  • Exceptional temperature uniformity and accuracy - due to advanced temperature control combined with high quality, precision engineered block providing excellent thermal contact.
  • Wide range of interchangeable aluminum blocks.
  • Heat to 105°C, optional external temperature probe.
  • Blocks optional available as accessories for all applications - tubes, vials, and microplates.
  • Block extraction tool is supplied, allowing blocks to be removed easily.
Picture
1. Specification for DBI-I Dry Bath Incubator:
  • Temperature Control Range. RT+5°C~105°C
  • Stability at 100°C: ≤0.5°C
  • Uniformity: within the block at 37°C±0.2°C
  • Heating time (25°C to 100°C): ≤20min
  • Display Accuracy / Display: 0.1°C / LED 
  • Timing Range: 1min~99h59min
  • Block Quantity: 1
  • External Size: 250*190 *130 mm
  • Package Size: 390*310*250mm
  • Net weight: 2.5kg
  • Gross weight: 4.1kg
Picture
2. Specification for DBI-II Dry Bath Incubator:
  • Temperature Control Range: RT+5°C~105°C
  • Stability at 100°C: ≤0.5°C
  • Uniformity: within the block at 37°C : ±0.2°C
  • Across similar blocks at 37°C : ±0.3°C
  • Heating time (25°C to 100°C): ≤20min
  • Display Accuracy / Display: 0.1°C / LED 
  • Timing Range: 1min~99h59min
  • Block Quantity: 2
  • External Size: 365*210*150mm
  • Package Size: 490*330*280mm
  • Net weight: 4.5kg
  • Gross weight:6.2kg
Picture
3. Specification for Dry Bath Incubator DBI-III:
  • Temperature Control Range: RT+5°C~100°C
  • Time required for temperature to increase from 20°C to 100°C: ≤15 min 
  • Temperature control discrepancy: ≤±0.5°C
  • Display discrepancy: ±0.1°C
  • Homogeneity of block temperature: ≤±0.5°C
  • Maximum heating power: 100W
  • Maximum temp. 100°C
  • Time Range: 1min~99h59 min
  • External Size: 225*160*197mm 
  • Package Size: 330*280*340mm
  • Net weight: 3kg
  • Gross weight: 6kg
Picture
4. Specification for Dry Bath Incubator DBI-IV:
  • Temperature Control Range: -10°C~100°C
  • Timing Range: 1min-99h59min
  • Temperature Control Accuracy: ≤±0.5°C
  • Display Accuracy: 0.1°C
  • Heating Time: ≤15min (from 20°C to 100°C) 
  • Cooling Time:
    ≤15min (from 20°C to -5°C) If the room temperature is lower 30“C
    ≤15min (from 20°C to -10°C) If the room temperature is Iower25°C 
  • External Size: 300*220*180 mm
  • Package Size. 480*380*330mm
  • Net weight: 5kg
  • Gross weight: 8kg
Picture
5. Specification for DBI-V Dry Bath Incubator:
  • Temperature Control Range: from 5°C above ambient to 80°C
  • Timing Range: 1min~999min or 1sec~999sec
  • Temperature Control Accuracy: ≤±0.5°C
  • Display Accuracy. 0.1°C
  • Heating Time: ≤12 min (from 25°C to 80°C)
  • Heating Parts: Heating Film
  • External Size: 150*110*100mm
  • Package Size: 260*200*170mm
  • Net weight: 0.5kg
  • Gross weight: 2kg
Picture
6. ​Specification for DBI-VI Dry Bath Incubator:
  • Temperature Control Range: from 5°C above ambient to 150°C
  • Time required for temperature to increase from 40°C to 150°C : ≤30min 
  • Temperature Control Discrepancy: ≤±0.5°C
  • Display Discrepancy: ±0.1°C
  • Homogeneity of Block Temperature: ≤±0.5°C 
  • Maximum Heated power: 200W
  • Dimension. 280*240*110mm
  • Time Range: 1~99h59min
  • External Size: 280*240*110mm
  • Package Size: 470*370*330mm
  • Net weight: 4.5kg
  • Gross weight: 7kg
Picture

Gel Card Incubator

Picture
Picture
Applications: 
Gel card incubator is matched with our gel cards centrifuge to use and holds 2 independent incubation zones with a capacity for 12 gel cards. It can be suitable for many types of gel cards from different manufacturers.

Features: 
  • Keep 24-Gel Cards in temperature of 37 degree.
  • LED display, time can be set.
  • Audible programmable alarm to notify end of incubation period.
  • Microprocessor PID temperature control, accurate and stable.
Technical Parameters:
Model
BK-GCI24
Capacity
24 cards
​Temperature
​37°C
Temperature Accuracy
<0.5°C
Temperature Uniformity 
±0.5°C
Time Range
0~99min59s
​Consumption
​250W
Power Supply
AC110/220V±10%, 50/60Hz 
​External Size (W*D*H)mm 
​280*390*140
Package Size (W*D*H)mm
445*335*190
​Net/Gross Weight(kg)
​6.2 / 8

Gel Card Centrifuge

Picture
Picture
Application:
Gel card centrifuge is used in blood serology, blood type routine test, erythrocyte washing, microcolumn agglutination, immunology, and other tests.

Features: ​
  • DC Brushless motor, low noise.
  • Microprocessor control system & soft touch control panel.
  • LCD display: RCF, Speed,Time.
  • Electric lid interlock, over speed and imbalance protection.
  • 20 programs for standard and programmability are available.
Technical Parameters:
Model
BKC-GC12
BKC-GC24
Max. Speed 
​3000rpm
​3000rpm
Max. RCF
830xg
​1080xg
Rotor
12 cards
​24 cards
​Speed Precision
​±20rpm
±20rpm
Time Range
​0~99min 
0~99min  
​Noise
​≤55dB
≤55dB
Power Supply
​AC110/220V±10%, 50/60Hz
​AC110/220V±10%, 50/60Hz
External Size(W*D*H)mm
483*320*265
​528*370*280
Package Size(W*D*H)mm
560*380*330
​610*435*340
​Gross Weight(kg)
24
30

Sample Concentration (Nitrogen Evaporator)

Picture
Features: 
  • High precision and wide range of temperature control. 
  • Blowing a large number of samples at one time.
  • Blowing each sample independently (Only for SC-II).
  • ​Amount of airflow can be adjusted.
  • Easy operation; safe and reliable to use.
Technical Parameters:
Model
SC-I
SC-II
​Temp. Range
​RT+5~150°C
​RT+5~150°C
​Low Nitrogen Consumption
​330mI/min/sample 
​330mI/min/sample 
Time Required from 40°C to 150°C
≤30 minutes
≤30 minutes
​Needles Length
​150mm
150mm
Temp. Control Discrepancy
​±0.1°C
​±0.1°C
​Consumption
200W
​400W
Power Supply
​AC110/220V±10%, 50/60Hz
​AC110/220V±10%, 50/60Hz
​External Size (L*D*H)
​280*240*500mm
280*240*500mm
Package Size (L*D*H)
​490*390*360mm
490*390*360mm
​N/G Weight
7/11kg
​7/11kg

TRIVANCED PTE. LTD.
All Rights Reserved @ Copyright 2025