Pipettes
TopPette-Mechanical Pipettes
Features for TopPette:
Features for Multi-channel TopPette:
|
MicroPette Mechanical Pipettes
Features for MicroPette:
Features for multi-channel MicroPette:
|
MicroPette Plus Autoclavable Pipette
Features for MicroPette plus:
Features for multi-channel MicroPette plus:
|
Fully Autoclavable:
The MicroPette plus pipettes can be fully autoclaved at 121°C, 1 atm for less than 20 mins. The pipettes can be autoclaved without special preparations. After autoclaving the pipette must be cooled down and dried over 12 hours.
Note: It is recommended to check the performance of the pipette after each autoclaving. It is also recommended to grease the piston and seal of the pipette after each 10 autoclaving.
The MicroPette plus pipettes can be fully autoclaved at 121°C, 1 atm for less than 20 mins. The pipettes can be autoclaved without special preparations. After autoclaving the pipette must be cooled down and dried over 12 hours.
Note: It is recommended to check the performance of the pipette after each autoclaving. It is also recommended to grease the piston and seal of the pipette after each 10 autoclaving.
Technical Parameters:
TopPette Mechanical Pipettes/ MicroPette Mechanical Pipettes / MicroPette Plus Autoclavable Pipettes (Adjustable and Fixed Volume).
*Single-channel Adjustable Volume Pipettes.
TopPette Mechanical Pipettes/ MicroPette Mechanical Pipettes / MicroPette Plus Autoclavable Pipettes (Adjustable and Fixed Volume).
*Single-channel Adjustable Volume Pipettes.
Volume Range |
Increment |
Test Volume(µl) |
Maximum Permissible Systematic |
Maximum Permissible Systematic |
Maximum Permissible Random |
Maximum Permissible Random |
0.1-2.5µI |
0.05µl |
2.5 |
2.50% |
0.0625µI |
2.00% |
0.05µl |
0.1-2.5µI |
0.05µl |
1.25 |
3.00% |
0.0375µI |
3.00% |
0.0375µI |
0.1-2.5µI |
0.05µl |
0.25 |
12.00% |
0.03µI |
6.00% |
0.015µI |
0.5-10µI |
0.1µI |
10 |
1.00% |
0.1µl |
0.80% |
0.08µl |
0.5-10µI |
0.1µI |
5 |
1.50% |
0.075µl |
1.59% |
0 075µl |
0.5-10µI |
0.1µI |
1 |
2.50% |
0.025µl |
1.50% |
0.015µl |
2-20µI |
0.5µI |
20 |
0.90% |
0.18µI |
0.40% |
0.08µl |
2-20µI |
0.5µI |
10 |
1.20% |
0.12µI |
1.00% |
0 1µl |
2-20µI |
0.5µI |
2 |
3.00% |
0.06µI |
2.00% |
0.04µl |
5.50µI |
0.5µI |
50 |
0.60% |
0.3µl |
0.30% |
0.15µl |
5.50µI |
0.5µI |
25 |
0.90% |
0.225µl |
0.60% |
0 15µl |
5.50µI |
0.5µI |
5 |
2.00% |
0.1µl |
2.00% |
0.1µl |
10-100µI |
1µI |
100 |
0.80% |
0.8µl |
0.15% |
0.15µl |
10-100µI |
1µI |
50 |
1.00% |
0.5µl |
0.40% |
0.2µl |
10-100µI |
1µI |
10 |
3.00% |
0.3µl |
1.50% |
0.15µl |
20-200µI |
1µl |
200 |
0.60% |
1.2µl |
0.15% |
0.3µl |
20-200µI |
1µl |
100 |
0.80% |
0.8µl |
0.30% |
0.3µl |
20-200µI |
1µl |
20 |
3.00% |
0.6µl |
1.00% |
0.2µl |
50-200µI |
1µl |
200 |
0.60% |
1.2µl |
0.15% |
0.3µl |
50-200µI |
1µl |
100 |
0.80% |
0.8µl |
0.30% |
0.3µl |
50-200µI |
1µl |
50 |
1.00% |
0.5µl |
0.40% |
0.2µl |
100-1000µI |
5µl |
1000 |
0.60% |
6µl |
0.20% |
2µl |
100-1000µI |
5µl |
500 |
0.70% |
3.5µl |
0.25% |
1.25µl |
100-1000µI |
5µl |
100 |
2.00% |
2µl |
0.70% |
0.7µl |
200-1000µI |
5µl |
1000 |
0.60% |
6µl |
0.20% |
2µl |
200-1000µI |
5µl |
500 |
0.70% |
3.5µl |
0.25% |
1.25µl |
200-1000µI |
5µl |
200 |
0.90% |
1.8µl |
0.30% |
0.6µl |
1000-5000µl |
50µl |
5000 |
0.50% |
25µl |
0.15% |
7.5µl |
1000-5000µl |
50µl |
2500 |
0.60% |
15µl |
0.30% |
7.5µl |
1000-5000µl |
50µl |
1000 |
0.70% |
7µl |
0.30% |
3µl |
2-10mI |
0.1ml |
10mI |
0.60% |
60µl |
0.20% |
20µl |
2-10mI |
0.1ml |
5mI |
1.20% |
60µl |
0.30% |
15µl |
2-10mI |
0.1ml |
2mI |
3.00% |
60µl |
0.60% |
12µl |
Note: 2-10ml is not available for micropette plus autoclavable pipettes
8-channel Adjustable Volume Pipettes:
Volume Range |
Increment |
Test Volume (II) |
Maximum Permissible Systematic Error |
Maximum Permissible Systematic Error |
Maximum Permissible Random Error |
Maximum Permissible Random Error |
0.5-10µI |
0.1µI |
10 |
1.50% |
0.15µI |
1.50% |
0.15µI |
0.5-10µI |
0.1µI |
5 |
2.50% |
0.125µI |
2.50% |
0.125µI |
0.5-10µI |
0.1µI |
1 |
4.00% |
0.04µI |
4.00% |
0.04µI |
5-50µI |
0.5µI |
50 |
1.00% |
0.04µI |
0.50% |
0.25µI |
5-50µI |
0.5µI |
25 |
1.50% |
0.375µI |
1.00% |
0.25µI |
5-50µI |
0.5µI |
5 |
3.00% |
0.15µI |
2.00% |
0.1µI |
50-300µI |
5µI |
300 |
0.70% |
2.1µI |
0.25% |
0.75µI |
50-300µI |
5µI |
150 |
1.00% |
1.5µI |
050% |
0.75µI |
50-300µI |
5µI |
50 |
1.50% |
0.75µI |
0.80% |
0.4µI |
12-channel Adjustable Volume Pipettes
Volume Range |
Increment |
Test Volume (UI) |
Maximum Permissible Systematic Error |
Maximum Permissible Systematic Error |
Maximum Permissible Random Error |
Maximum Permissible Random Error |
0.5-10µI |
0.1µI |
10 |
1.50% |
0.15µI |
1.50% |
0.15µI |
0.5-10µI |
0.1µI |
5 |
2.50% |
0.125µI |
2.50% |
0.125µI |
0.5-10µI |
0.1µI |
1 |
4.00% |
0.04µI |
4.00% |
0.04µI |
5-10µI |
0.5µI |
50 |
1.00% |
0.5µI |
0.50% |
0.25µI |
5-10µI |
0.5µI |
25 |
1.50% |
0.375µI |
1.00% |
0 25µI |
5-10µI |
0.5µI |
5 |
3.00% |
0.15µI |
2.00% |
0.1µI |
50-300µI |
5µI |
300 |
0.70% |
2.1µI |
0.25% |
0.75µI |
50-300µI |
5µI |
150 |
1.00% |
1.5µI |
0.50% |
0 75µI |
50-300µI |
5µI |
50 |
1.50% |
0.75µI |
0.80% |
0.4µI |
Fixed Volume Pipettes:
Volume Range |
Increment |
Test Volume (II) |
Maximum Permissible Systematic Error |
Maximum Permissible Systematic Error |
Maximum Permissible Random Error |
Maximum Permissible Random Error |
5µI |
/ |
5µI |
1.3% |
0.065µI |
1.2% |
0.06µI |
10µI |
/ |
20µI |
0.8% |
0.08µI |
0.8% |
0.08µI |
20µI |
/ |
20µI |
0.6% |
0.12µI |
0.5% |
0.1µI |
25µI |
/ |
25µI |
0.5% |
0.125µI |
0.3% |
0.075µI |
50µI |
/ |
50µI |
0.5% |
0.25µI |
0.3% |
0.15µI |
100µI |
/ |
100µI |
0.5% |
0.5µI |
0.3% |
0.3µI |
200µI |
/ |
200µI |
0 .4% |
0.8µI |
0.2% |
0.4µI |
250µI |
/ |
250µI |
0.4% |
1.0µI |
0.2% |
0.5µI |
500µI |
/ |
500µI |
0.3% |
1.5µI |
0.2% |
1.0µI |
1000µI |
/ |
1000µI |
0.3% |
3.0µI |
0.2% |
2.0µI |
2000µI |
/ |
2000µI |
0.3% |
6.0µI |
0.15% |
3.0µI |
5000µI |
/ |
5000µI |
0.3% |
15µI |
0.15% |
7.5µI |
Levo Plus Pipette Filler
Features:
|
Technical Parameters:
Aspirate Speeds |
8 |
Dispense Speed |
8 levels Gravity Dispense |
Battery |
Lithium-Ion |
Battery Working Time |
8 hours of intermittence use |
Charging Time |
Approx 2 hours |
Pipette |
Glass or Plastic Pipette (0.1-100mI), Pasteur Pipettes |
Filter |
0.45 µm Hydrophobic |
Ordering information:
Cat No. |
Descriptions |
7033100100 |
|
Cat No. |
Standard accessories |
17400032 |
Levo Plus charger |
17000205 |
Levo Plus Lithium battery |
17000103 |
Filter 0.45 µm. 1pc/pk |
Electronic Pipette
Features:
|
Technical Parameters:
Volume Range |
Increment |
Test Volume (µL) |
Inaccuracy (µL) |
Inaccuracy (%) |
Imprecision (s.d.* µL) |
Imprecision (CV*%) |
0.5-10µL |
0.01µL |
10 |
±0.40 |
±1.0 |
0.05 |
0.5 |
0.5-10µL |
0.01µL |
1 |
±0.035 |
±3.5 |
0.03 |
3.0 |
5-50µL |
0.1µL |
50 |
±0.40 |
±0.8 |
0.15 |
0.3 |
5-50µL |
0.1µL |
5 |
±0.15 |
±3.0 |
0.125 |
25 |
30-300µL |
1µL |
300 |
±1.8 |
±0.6 |
0,6 |
0.2 |
30-300µL |
1µL |
30 |
±0.9 |
±3.0 |
0.21 |
0.7 |
100-1000µL |
5µL |
1000 |
±6.0 |
±0.6 |
2.0 |
0.2 |
100-1000µL |
5µL |
100 |
±3.0 |
±3.0 |
0.6 |
0.6 |
*s.d.is Standard Deviation
*CV is Coefficient of Variation
*CV is Coefficient of Variation
Pipette Stand
Ordering Informations:
Cat. No |
Descriptions |
7030000084 |
Round stand holds up to 6 pipettes, fit of TopPette, MicroPette and MicroPette Plus |
7030000085 |
Linier stand holds up to 6 pipettes, fit of TopPette, MicroPette and MicroPette Plus |