Technical Parameters:
Model |
PH-105/F/L |
PH-205/F/L |
PH-30S/F/L |
PH-40 |
pH Range |
0.0~14.0pH |
-1.00~15.00pH |
-1.00~15.00pH |
-1.00~15.00pH |
pH Accuracy |
±0.1pH |
±0.01 pH |
±0.01 pH |
±0.01 pH |
Calibration Points |
2 points |
1~3 points |
1~3 points |
1~3 points |
Calibration Solutions |
USA (pH4.01/7.00/10.01) |
USA (pH4.01/7.00/10.01) |
USA (pH4.01/7.00/10.01) |
USA (pH4.01/7.00/10.01) |
Temp. Compensation |
/ |
0 60°C, Automatic |
0 60°C, Automatic |
0~100°C, Manual |
Hold Function |
Manual |
Manual or Automatic |
Manual or Automatic |
Manual or Automatic |
Connector |
6-pin |
6-pin |
6-pin |
BNC |
Power Requirements |
3x1.SV "G13A” batteries |
2x1.5V ”AAA" batteries |
2x1.5V ”AAA" batteries |
2x1.5V ”AAA" batteries |
Dimensions(L*D) |
185*40mm |
185*40mm |
185*40mm |
185*40mm |
Package Size(W*D*H) |
325*124*270mm |
325*124*270mm |
325*124*270mm |
325*124*270mm |
Net Weight |
100g |
100g |
100g |
100g |
Gross Weight |
1kg |
1kg |
1kg |
1kg |
Portable pH/ORP Meter
pH Mode (For PH-221/320):
ORP Mode (For PH221/320):
|
Features:
Ion Concentration Mode (For PH-320):
Accessories:
|
Technical Parameters:
Model |
PH-220 |
PH-221 |
PH-320 |
pH Range |
-2.00~16.00pH |
-2.000~20.000pH |
-2.000~20.000pH |
pH Accuracy |
±0.01 pH |
±0.002pH |
±0.002pH |
Resolution |
0.01pH |
0.1, 0.01, 0.001pH, Selectable |
0.1, 0.01, 0.001pH, Selectable |
Calibration Points |
2 points |
1~5 points |
1~5 points |
Calibration Solutions |
USA (pH4.01/7.00/10.01) |
USA(pH1.68/4.01/7.00/10.01/12.45),NIST(pH1.68/4.01/6.86/9.18/12.45),DIN(pH1.09/4.65/6.79/9.23/12.75) or User-defined |
USA(pH1.68/4.01/7.00/10.01/12.45(pH1.68/4.01/6.86/9.18/12.45)DIN(pH1.09/4.65/6.79/9.23/12.75) or User-defined |
Temp. Compensation |
0~100°C, 32~212°F, Manual or Automatic |
0~100°C, 32 212°F, Manual or Automatic |
0~100°C, 32~21 2°F, Manual or Automatic |
mV Range |
-1999~1999mV |
-1999.9~1999.9mV |
-1999.9~1999.9mV |
mV Accuracy |
±1mV |
±0.2mV |
±0.2mV |
Resolution |
1mV |
0.1, 1mV, Selectable |
0.1, 1mV, Selectable |
Calibration Points |
/ |
1 point (Only for Relative mV mode) |
1 point (Only for Relative mV mode) |
Ion Concentration Range |
/ |
/ |
0 001~19999ppm, mg/L, mol/L (Refer to the range of ISE) |
Ion Concentration Accuracy |
/ |
/ |
±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
Calibration Points |
/ |
/ |
2~5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L) |
Temp. Range |
0~100°C, 32-212°F |
0~105°C, 32-221°F |
/ |
Temp. Accuracy |
±1°C |
±0.5°C, +0.9°F |
/ |
Resolution |
0.1°C |
/ |
/ |
Hold Function |
Manual |
/ |
/ |
Memory |
Stores up to 50 data sets |
Stores up to 500 data sets |
Stores up to 500 data set |
Output |
/ |
USB Communication Interface |
USB Communication Interface |
Connector |
BNC |
BNC |
/ |
Power Requirements |
1x9V/800mA battery |
3x1.SV "AA" batteries (Standard) or DCSV power adapter(Optional) |
3x1.5V"AA" batteries (Standard) or DCSV power adapter(Optional) |
Dimensions(W*D*H) |
185*88*32mm |
170*85*30mm |
170*85*30mm |
Package Size(W*D*H) |
475*155*350mm |
475*155*350mm |
475*155*350mm |
Net Weight |
300g |
300g |
300g |
Gross Weight |
2kg |
2kg |
2kg |
Portable Ion Meter
Features:
- 2 to 5 points calibration from low to high concentrations.
- Direct ion concentration readout simplifies the elaborate measurement process.
- Selectable multiple concentration units include the ppm, mg/L and mol/L.
- mV measurement mode allows checking the performance of ion selective electrode.
- Automatic Temperature Compensation ensures accurate measured values.
- Calibration Due Reminder prompts user to calibrate the meter regularly.
- Stability indicator automatically shows current measurement status.
- Auto-Hold function freezes stable reading for easy viewing and recording.
- Selectable temperature unit ( °C or °F ) meets different application requirements.
- Automatic electrode diagnosis shows offset and electrode slope.
- Help message as a operational guide that helps you quickly begin using the meter.
- System menu allows setting the 8 parameters, including the ion valence, number of calibration points, stability condition, etc.
- Reset feature automatically resumes parameters back to factory default options.
- Expanded memory stores and recalls up to 500 readings.
- Built-in real-time clock stamps stored data to meet GLP standard.
- Stored data can be transferred into computer by USB communication interface
Accessories: Ion Selective Electrode (Chosen by the customer), temperature probe, batteries and carrying case.
Technical Parameters:
Model |
PH-321 |
Ion Concentration Range |
Refer to the range of ISE |
Ion Concentration Accuracy |
±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
Resolution |
0.001, 0.01, 0.1, 1 |
Calibration Points |
2~5 points |
Calibration Solutions |
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
Temperature Compensation |
0~100°C, 32~212°F, Manual or Automatic |
mV Range |
-1999.9~1999.9mV |
Mv Accuracy |
±0.2mV |
Resolution |
0.1, 1mV, Selectable |
Hold Function |
Manual or Automatic |
Stability Conditions |
Low or High |
Power Off |
Manual or Automatic (10, 20, 30 minutes) |
Memory |
Stores up to 500 data sets |
Output |
USB Communication Interface |
Connector |
BNC |
Power Requirements |
3x1.5V "AA" batteries (Standard) or DCSV power adapter (Optional) |
Dimensions |
170*85*30mm |
Package Size(W*D*H) |
475*155*350mm |
Net Weight |
300g |
Gross Weight |
2kg |
Benchtop pH Meter
PHS-25CW/3BW Features:
Accesories:
Technical Parameters:
|
PH-210 Features:
|
Model |
PHS-25CW |
PHS-3BW |
PH-210 |
pH Range |
0.00~14.00pH |
0.00~14.00pH |
-1.00~15.00p |
PH Accuracy |
±0.05pH |
±0.01pH |
±0.01pH |
Resolution |
0.01pH |
0.01pH |
0.01pH |
Calibration Points |
2 points |
2 points |
1~3 points |
Calibration Solutions |
USE (pH4.01/7.00/10.01) |
USE (pH4.01/7.00/10.01) |
USE (pH4.01/7.00/10.01) NIST (pH4.01/6.86/9.18) |
Temp.Compensation |
0~100°C, Manual |
0~100°C, Manual |
0~100°C, 32~212°F Manual or Automatic |
mV Range |
-1999~1999mV |
-1999~1999mV |
-1999~1999mV |
mV Accurancy |
±10mV |
±1mV |
±1mV |
Resolution |
1mV |
1mV |
1mV |
Temp. Range |
/ |
0~100°C |
0~105°C, 32~221°F |
Temp. Accurancy |
/ |
±1°C |
±1°C |
Resolution |
/ |
1°C |
0.1°C |
Hold Function |
/ |
/ |
Manual or Automatic |
Connecter |
BNC |
BNC |
BNC |
Display |
LCD |
LCD |
LCD (135*75mm) |
Power Requirenments |
DC9V/400mA Power Adapter |
DC9V/400mA Power Adapter |
DC9V/400mA Power Adapter |
Dimensions (W*D*H) |
210*240*180mm |
210*240*180mm |
210*205*75mm |
Package Size (W*D*H) |
310*240*180mm |
310*240*180mm |
310*240*180mm |
Net Weight |
1.5kg |
1.5kg |
1.5kg |
Gross Weight |
1.7kg |
1.7kg |
1.7kg |
Benchtop pH/ORP/Ion Meter
pH Mode:
ORP Mode:
|
Ion Concentration Mode (For PH-930):
|
Accessories:
|
Other Features:
- Auto-Hold function freezes stable reading for easy viewing and recording.
- Automatic electrode diagnosis shows offset and electrode slope.
- Expanded memory stores and recalls up to 500 readings.
- Built-in real-time clock stamps stored data to meet GLP standard.
Technical Parameters:
Model |
PH-920 |
PH-830 |
pH Range |
-2.000~20.000pH |
-2.000~20.000pH |
pH Accuracy |
±0.002pH |
±0.002pH |
Resolution |
0.1, 0.01, 0.001pH, Selectable |
0.1, 0.01, 0.001pH, Selectable |
Calibration Points |
1~5 point |
1~5 points |
Calibration Solutions |
USA (pH1.68/4.01/7.00/10.01/12.45), NIST (pH1.68/4.01/6.86/9.18/12.45), DIN (pH1.09/4.65/6.79/9.23/12.75) or User-defined |
USA (pH1.68/4.01/7.00/10.01/12.45), NIST (pH1.68/4.01/6.86/9.18/12.45), DIN (pH1.09/4.65/6.79/9.23/12.75) or User-defined |
Temp. Compensation |
0~100°C, 32-212°F, Manual or Automatic |
0~100°C, 32-212°F, Manual or Automatic |
mV Range |
-1999.9~1999.9mV |
-1999.9~1999.9mV |
mV Accuracy |
±02mV |
±02mV |
Resolution |
0.1, 1mV, Selectable |
0.1, 1mV, Selectable |
Calibration Points |
1 point (Only for Relative mV mode) |
1 point (Only for Relative mV mode) |
Ion Concentration Range |
/ |
0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE) |
Ion Concentration Accuracy |
/ |
±10.5% F.S (Monovalent), ±1% F.S (Divalent) |
Temp. Range |
0~105°C, 32~221°F |
0~105°C, 32~221°F |
Temp. Accuracy |
±0.5°C, +0.9°F |
±0.5°C, +0.9°F |
Calibration Points |
/ |
2-5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L) |
Memory |
Stores up to 500 data sets |
Stores up to 500 data sets |
Output |
USB Communication Interface |
USB Communication Interface |
Connector |
BNC |
/ |
Power Requirements |
DC5V/400mA power adapter |
DC5V/400mA power adapter |
Dimensions(W*D*H) |
210*188*60mm |
210*188*60mm |
Package Size(W*D*H) |
310*240*180mm |
310*240*180mm |
Net Weight |
1.5kg |
1.5kg |
Gross Weight |
1.7kg |
1.7kg |
Portable Conductivity/TDS/Salinity Meter
Features:
|
Accessories:
Conductivity electrode, temperature probe, conductivity standard solutions 84µS/cm, 1413µS/cm, 12.88mS/cm), batteries and carrying case. |
Technical Parameters:
Model |
PH-520 |
PH-530 |
PH-531 |
PH-540 |
Conductivity Range |
0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Conductivity Accuracy |
±10.5% F.S |
±10.5% F.S |
±10.5% F.S |
±10.5% F.S |
TDS Range |
/ |
0~100ppt (Max. 200ppt, depending on factor setting) |
/ |
0~100ppt (Max. 200ppt depending on factor setting) |
TDS Accuracy |
/ |
±1% F.S |
/ |
±1% F.S |
Salinity Range |
/ |
/ |
0~10ppt (Max. 80ppt) |
0~10ppt (Max. 80ppt) |
Salinity Accuracy |
/ |
/ |
±1% F.S |
±1% F.S |
Resistivity Range |
/ |
/ |
/ |
0~100MƱ |
Resistivity Accuracy |
/ |
/ |
/ |
1% F.S |
Calibration Points |
1~3 points (Model 520A), 1~5 points {Model 530/531/540) |
1~3 points (Model 520A), 1~5 points {Model 530/531/540) |
1~3 points (Model 520A), 1~5 points {Model 530/531/540) |
1~3 points (Model 520A), 1~5 points {Model 530/531/540) |
Calibration Solutions |
10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111 .8mS/cm |
10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111 .8mS/cm |
10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111 .8mS/cm |
10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111 .8mS/cm |
Temperature Compensation |
0~100°C, 32~212°F, Manual or Automatic |
0~100°C, 32~212°F, Manual or Automatic |
0~100°C, 32~212°F, Manual or Automatic |
0~100°C, 32~212°F, Manual or Automatic |
Temperature Coefficient |
0.0~10.0%/°C |
0.0~10.0%/°C |
0.0~10.0%/°C |
0.0~10.0%/°C |
Normalization Temperature |
25°C (Model 520A), 20°C or 25°C (Model 530/531/540) |
25°C (Model 520A), 20°C or 25°C (Model 530/531/540) |
25°C (Model 520A), 20°C or 25°C (Model 530/531/540) |
25°C (Model 520A), 20°C or 25°C (Model 530/531/540) |
Cell Constant |
K=0 1, 1, 10 or User-defined |
K=0 1, 1, 10 or User-defined |
K=0 1, 1, 10 or User-defined |
K=0 1, 1, 10 or User-defined |
Memory |
Stores up to 500 data sets, USB Communication Interface |
Stores up to 500 data sets, USB Communication Interface |
Stores up to 500 data sets, USB Communication Interface |
Stores up to 500 data sets, USB Communication Interface |
Power Requirements |
3x1.SV ”AA” batteries (Standard) or DCSV power adapter (Optional) |
3x1.SV ”AA” batteries (Standard) or DCSV power adapter (Optional) |
3x1.SV ”AA” batteries (Standard) or DCSV power adapter (Optional) |
3x1.SV ”AA” batteries (Standard) or DCSV power adapter (Optional) |
Dimensions |
170*85*30mm |
170*85*30mm |
170*85*30mm |
170*85*30mm |
Package Size(W*D*H) |
475*155*350mm |
475*155*350mm |
475*155*350mm |
475*155*350mm |
Net Weight |
300g |
300g |
300g |
300g |
Gross Weight |
2kg |
2kg |
2kg |
2kg |
Benchtop Conductivity/TDS/Salinity/Resistivity Meter
Accessories:
|
Features:
|
|
Technical Parameters:
Model |
PH-950 |
Conductivity Range |
0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Conductivity Accuracy |
±10.5% F.S |
TDS Range |
0~100ppt (Max. 200ppt, depending on factor setting) |
TDS Accuracy |
±1% F.S |
Salinity Range |
0~10ppt (Max. 80ppt) |
Salinity Accuracy |
±1% F.S |
Resistivity Range |
0~100MƱ |
Resistivity Accuracy |
±1% F.S |
Calibration Points |
1~5 points |
Calibration Solutions |
10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
Temp. Compensation |
0~100°C, 32~212°F, Manual or Automatic |
Temp Coefficient |
0.0~10.D%/°C |
Normalization Temp. |
20°C or 25°C |
Cell Constant |
K=0.1, 1, 10 or User-defined |
Memory |
Stores up to 500 data sets, USB Communication Interface |
Power Requirements |
DC5V/400mA power adapter |
Dimensions(W*D*H) |
210*188*60mm |
Package Size(W*D*H) |
310*240*180mm |
Net Weight |
1.5kg |
Gross Weight |
1.7kg |
Portable Dissolved Oxygen Meter
Features:
|
Other features for PH-821:
Accessories:
Dissolved oxygen electrode, electrolyte solution, membrane cap, batteries, and carrying case. |
Technical Parameters:
Model |
PH-820 |
PH-821 |
Dissolved Oxygen Range |
0.0~20.0mg/L (or ppm) |
0.00~20.00mg/L (or ppm) |
Accuracy |
±0.5mg/ |
±0.2mg/L |
Resolution |
0.1mg/L |
0.01 mg/L |
% Saturation of Oxygen |
0.0~200.0% |
0.0~200.0% |
Accuracy |
±10% F.S |
±2.0% F.S |
Resolution |
0.1% |
0.1, 1% |
Calibration Points |
1~2 point |
1~2 points |
Temperature Compensation |
0~40°C, 32~104°F, Automatic |
0~50°C, 32~122°F, Automatic |
Barometric Pressure Correction |
60.0~112.5kPa, 450~850mmHg |
60.0~112.5kPa, 450~850mmHg |
Salinity Correction |
0~35g/L |
0~50g/L |
Hold Function |
Manual |
Manual or Automatic |
Memory |
Stores up to 4B data sets |
Manual or Automatic (10, 20, 30 minutes) |
Sensor Type |
Polarographic Dissolved Oxygen Electrod |
Stores up to 500 data sets |
Connector |
4-pin mini plug |
USB Communication Interface |
Power Requirements |
1x9V/800mA battery |
6-pin mini plug |
Battery Life |
Approximately 150 hours |
3x1.5V "AA" batteries (Standard) or DCSV power adapter (Optional) |
Dimensions |
185*88*32mm |
185*88*32mm |
Package Size(W*D*H) |
475*155*350mm |
475*155*350m |
Net Weight |
300g |
300g |
Gross Weight |
2kg |
2kg |
Benchtop Dissolved Oxygen Meter
Accessories:
PH-980
|
Features:
|
Technical Parameters:
Model |
PH-810 |
PH-980 |
Dissolved Oxygen Range |
0.0~20.0mg/L (or ppm) |
0.00~20.00mg/L (or ppm |
Accuracy |
±0.5mg/L |
±0.2mg/ |
Resolution |
0.1mg/L |
0.01mg/L |
% Saturation of Oxygen |
0.0~200.0% |
0.0-200.0% |
Accuracy |
±10°% |
±2.0% F.S |
Resolution |
0.1% |
0.1, 1% |
Calibration Points |
1~2 points |
1~2 points |
Temp. Compensation |
0~40°C, 32~104°F, Automatic |
0~50°C, 32~122°F, Automatic |
Barometric Pressure Correction |
60.0~112.5kPa, 450~850mmHg |
60.0~112.5kPa, 450~850mmHg |
Salinity Correction |
0~35g/L |
0~50g/L |
Hold Function |
Manual or Automatic |
Manual or Automatic |
Power Off |
Manual or Automatic (180 minutes) |
Manual or Automatic (10, 20, 30 minutes) |
Memory |
/ |
Stores up to 500 data sets |
Reset Function |
Yes |
/ |
Output |
/ |
USB Communication Interface |
Connector |
6-pin mini plug |
6-pin mini plug |
Display |
LCD (135x75mm) |
/ |
Power Requirements |
DC9V/400mA power adapter |
DC5V/400mA power adapter |
Dimensions(W*D*H) |
210*205*75mm |
210*188*60mm |
Package Size(W*D*H) |
310*240*180mm |
310*240*180m |
Net Weight |
1.5kg |
1.5kg |
Gross Weight |
1.7kg |
1.7k |
Portable Water Hardness Meter
Features:
|
Other features for PH-821:
Accessories: Water hardness electrode, temperature probe, batteries and carrying case.
|
Technical Parameters:
Model |
PH-322 |
Water Hardness Range |
0.05mmol/L~0.2mol/L, 0~19999mg/L (CaCO ), OU1220mg/L (CaO), |
Water Hardness Range |
0~400mmoI/L (Boiler), 0~8020mg/L (Ca) |
Water Hardness Range |
0~1122°dH (German Degree), 0~2000°f (French Degree), 0~1404°e (English Degree) |
Accuracy |
±1% F.S |
Calibration Points |
2~5 points |
Calibration Solutions |
0.001, 0.01, 0.1mmoI/L, mol/L |
Temperature Compensation |
0~50°C, 32~122°F, Manual or Automatic |
mV Range |
-1999.9~1999.9mV |
mV Accuracy |
±0.2mV |
Resolution |
0.1, mV, Selectable |
Hold Function |
Manual or Automatic |
Stability Conditions |
Low or High |
Power Off |
Manual or Automatic (10, 20, 30 minutes) |
Memory |
Stores up to 500 data sets |
Output |
USB Communication Interface |
Connector |
BNC |
Power Requirements |
3x1.5V "AA" batteries (Standard) or DCSV power adapter (Optional) |
Dimensions |
170*85*30mm |
Package Size(W*D*H) |
475*155*350mm |
Net Weight |
300g |
Gross Weight |
2kg |
Benchtop Water Hardness Meter
Features:
|
Accessories:
|
Technical Parameters:
Model |
PH-932 |
Water Hardness Range |
0.05mmol/L~0.2mol/L, 0~19999mg/L (CaCO ), 0~1122Omg/L (CaO), 0~400mmoI/L (Boiler), 0~8020mg/L (Ca), 0~1122°dH (German Degree), 0~2000°F (French Degree), 0~1404°e (English Degree) |
Accuracy |
±1% F.S |
Calibration Points |
2~5 points |
Calibration Solutions |
0.001, 0.01, 0.1mmol/L, mol/L |
Temp. Compensation |
0~50°C, 32~122°F, Manual or Automatic |
mV Range |
-1999.9~1999.9mV |
mV Accuracy |
±0.2mV |
Resolution |
0.1, 1mV, Selectable |
Hold Function |
Manual or Automatic |
Stability Conditions |
Low or High |
Power Off |
Manual or Automatic (10, 20, 30 minutes) |
Memory |
Stores up to 500 data sets |
Output |
USB Communication Interface |
Connector |
BNC |
Power Requirements |
DC5V/400mA power adapter |
Dimensions (W*D*H) |
210*188*60mm |
Package Size (W*D*H) |
310*240*180mm |
Net Weight |
1.5kg |
Gross Weight |
1.7kg |
Portable Multiparameter Water Quality Meter
Other Features:
|
Features:
PH Mode:
Ion Concentration Made:
Accessories: Temperature probe. Calibration solutions. Batteries.
A Carrying case. pH, conductivity, and dissolved oxygen electrodes. |
Technical Parameters:
Model |
PH-900P |
|
PH |
Range |
-2.000~20.000pH |
PH |
Accuracy |
±0.002pH |
PH |
Calibration Points |
1~5 points |
PH |
Calibration Solutions |
USA, NIST. DIN or User-defined |
ORP |
Range |
-1999.9~1999.9mV |
ORP |
Accuracy |
±0.2mV |
ORP |
Calibration Points |
1 point |
ORP |
Measurement Modes |
mV and Relative mV |
Ion |
Range |
0~19999ppm, mg/L, mol/L (Depending on range of ISE) |
Ion |
Accuracy |
±0.5% F S (Manovalent), ±1% F.S (Divalent) |
Ion |
Calibration Points |
2~5 points |
Ion |
Calibration Solutions |
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L |
Conductivity |
Range |
0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Conductivity |
Accuracy |
±0.5% F.S |
Conductivity |
Calibration Points |
1~5 points |
Conductivity |
Calibration Solutions |
10µS/cm, 84µS/cm, 1413µS/cm,12.88mS/cm,111.8mS/cm |
Conductivity |
Temperature Coefficient |
0.0-10.0%/°C |
Conductivity |
Compensation Modes |
Linear or Pure Water |
Conductivity |
Cell Constant |
K=0.1, 1, 10 or User-defined |
Conductivity |
Normalization Temperature |
20°C or 25°C |
TDS |
Range |
0~100ppt (Max. 200ppt, depending on factor setting) |
TDS |
Accuracy |
±1% F.S |
TDS |
TDS Factor |
0.1~1.0 (Default 0.5) |
Salinity |
Range |
0~10ppt (Max. 80ppt) |
Salinity |
Accuracy |
±1% F.S |
Salinity |
Measurement Modes |
Seawater or Practical Salinity |
Resistivity |
Range |
0~100MΩ |
Resistivity |
Accuracy |
±1% F.S |
Resistivity |
Resolution |
0.01, 0.1, 1 |
Dissolved Oxygen |
Concentration Range |
0.00~20.00mg/L (or ppm) |
Dissolved Oxygen |
Accuracy |
±0.2mg/L |
Dissolved Oxygen |
Calibration Points |
1~2 points |
Dissolved Oxygen |
Pressure Correction |
60.0~112.5kPa, 450~850mmHg |
Dissolved Oxygen |
Salinity Correction |
0~50g/L |
Dissolved Oxygen |
% Saturation of Oxygen |
0.0~200.0% |
Dissolved Oxygen |
Accuracy |
±2.0% |
Temperature |
Range |
0~105°C/32~221°F |
Temperature |
Resolution |
0.1°C/0.1° F |
Temperature |
Accuracy |
±0.5°C/±0.9°F |
Temperature |
Offset Calibration |
1 point, measured value: ±10°C |
Others |
Temperature Compensation |
0~100°C, 32~212°F. Manual or Automatic |
Others |
Stability Conditions |
Low or High |
Others |
Calibration Due |
0 to 31 days |
Others |
Memory |
Stores up to 500 data sets |
Others |
Output |
USB Communication Interface |
Others |
Power Requirements |
3x1.5V "AA" batteries (Standard) or DCSV power adapter (Optional) |
Others |
Dimensions |
185*’88*32mm |
Others |
Package Size(W*D”H) |
475*155*350mm |
Others |
Net Weight |
300g |
Others |
Gross Weight |
2kg |
Benchtop Multiparameter Water Quality Meter
Other Features:
|
Measurement Modes:
PH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity and Dissolved Oxygen. Features: PH Mode:
ORP Mode:
|
Technical Parameters:
Model |
PH-900 |
|
PH |
Range |
-2.000~20.000pH |
PH |
Accuracy |
±0.002pH |
PH |
Calibration Points |
1~5 points |
PH |
Calibration Solutions |
USA, NIST. DIN or User-defined |
ORP |
Range |
-1999.9~1999.9mV |
ORP |
Accuracy |
±0.2mV |
ORP |
Calibration Points |
1 point |
ORP |
Measurement Modes |
mV and Relative mV |
Ion |
Range |
0~19999ppm, mg/L, mol/L (Depending on range of ISE) |
Ion |
Accuracy |
±0.5% F S (Manovalent), ±1% F.S (Divalent) |
Ion |
Calibration Points |
2~5 points |
Ion |
Calibration Solutions |
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L |
Conductivity |
Range |
0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Conductivity |
Accuracy |
±0.5% F.S |
Conductivity |
Calibration Points |
1~5 points |
Conductivity |
Calibration Solutions |
10µS/cm, 84µS/cm, 1413µS/cm,12.88mS/cm,111.8mS/cm |
Conductivity |
Temperature Coefficient |
0.0-10.0%/°C |
Conductivity |
Compensation Modes |
Linear or Pure Water |
Conductivity |
Cell Constant |
K=0.1, 1, 10 or User-defined |
Conductivity |
Normalization Temperature |
20°C or 25°C |
TDS |
Range |
0~100ppt (Max. 200ppt, depending on factor setting) |
TDS |
Accuracy |
±1% F.S |
TDS |
TDS Factor |
0.1~1.0 (Default 0.5) |
Salinity |
Range |
0~10ppt (Max. 80ppt) |
Salinity |
Accuracy |
±1% F.S |
Salinity |
Measurement Modes |
Seawater or Practical Salinity |
Resistivity |
Range |
0~100MΩ |
Resistivity |
Accuracy |
±1% F.S |
Resistivity |
Resolution |
0.01, 0.1, 1 |
Dissolved Oxygen |
Concentration Range |
0.00~20.00mg/L (or ppm) |
Dissolved Oxygen |
Accuracy |
±0.2mg/L |
Dissolved Oxygen |
Calibration Points |
1~2 points |
Dissolved Oxygen |
Pressure Correction |
60.0~112.5kPa, 450~850mmHg |
Dissolved Oxygen |
Salinity Correction |
0~50g/L |
Dissolved Oxygen |
% Saturation of Oxygen |
0.0~200.0% |
Dissolved Oxygen |
Accuracy |
±2.0% |
Temperature |
Range |
0~105°C/32~221°F |
Temperature |
Resolution |
0.1°C/0.1° F |
Temperature |
Accuracy |
±0.5°C/±0.9°F |
Temperature |
Offset Calibration |
1 point, measured value: ±10°C |
Others |
Temperature Compensation |
0~100°C, 32~212°F. Manual or Automatic |
Others |
Stability Conditions |
Low or High |
Others |
Calibration Due |
0 to 31 days |
Others |
Memory |
Stores up to 500 data sets |
Others |
Output |
USB Communication Interface |
Others |
Power Requirements |
3x1.5V "AA" batteries (Standard) or DCSV power adapter (Optional) |
Others |
Dimensions |
210*188*60mm |
Others |
Package Size(W*D”H) |
310*240*180mm |
Others |
Net Weight |
1.5kg |
Others |
Gross Weight |
1.7kg |