Kjeldahl Apparatus
Semi Automatic Kjeldahl Nitrogen Analyzer (Kjeldahl Distiller)
Features for BKN-984:
|
Fully Automatic Kjeldahl Nitrogen Analyzer
Features for BKN-110F and BKN-986:
|
Technical Parameters:
Model |
BKN-984 |
BKN-110F |
BKN-986 |
Water Consumption |
1.5L/Min |
1.5L/Min |
1.5L/Min |
Ambient Temperature |
5~40°C |
5~40°C |
5~40°C |
Ambient Humidity |
80% |
80% |
80% |
Measure Range |
0.1mg~200mg |
0.1mg~200mg |
0.1mg~200mg |
Analysis Time |
5~10min |
5~10min |
5~10min |
Recovery Ratio |
≥99.5% |
≥99.5% |
≥99.5% |
Sample Amount |
Solid ≤6g; Liquid ≤16ml |
Solid ≤5g; Liquid ≤20mI |
Solid ≤5g; Liquid ≤20mI |
Burette Accuracy |
/ |
1.0µL/step |
2µL/step |
Reproducibility |
/ |
±0.5% |
±0.5% |
Consumption |
2000W |
2000W |
2000W |
Power Supply |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
AC110/220V±10%, 50/60Hz |
Packing Size (W*D*H) |
655*528*880mm |
Main body: 585*525*900mm Accessories: 605*600*355mm |
Main body: 585*525*905mm Accessories: 600*600*360mm |
Gross Weight |
45kg |
Main body: 52.7kg, Accessories: 12.5kg |
Main body: 50.3kg, Accessories. 13.4kg |
Functions List |
BKN-984 |
BKN-110F |
BXN-986 |
Variable Steam Generator |
• |
• |
• |
Cooling Water Pressure Monitor |
• |
• |
• |
Cooling Water Temperature Monitor |
• |
• |
• |
Automatic Alkali Solution Adding |
• |
• |
• |
Automatic Dilute Water |
• |
• |
• |
Auto Receiver Solution Adding |
• |
• |
• |
Tube Emptying |
• |
||
Removable Drain Tray |
• |
• |
• |
Safety Door |
• |
• |
• |
Tube on Position Sensor |
• |
• |
|
Tube Replacement Sensor |
• |
• |
|
Colorimetric Titration Device |
• |
• |
|
Results Calculation |
• |
• |
|
Result and Data Storing |
• |
• |
|
Built-in Printer |
• |
• |
|
Trouble Shooting Self-Detecting Functions |
• |
• |
• |
Titration While Distillation |
• |
Kjeldahl Digestion Furnace
Technical Parameters:
Model |
BKD-20F |
Temp. Range |
RT+5~450°C |
Temp. Accuracy |
±14 |
Heating Method |
Infrared heating and high-purity graphite conduction |
Heating Insulation Method |
Ceramic fiber and unique air duct insulation |
Digestion Tube Capacity |
300ml |
Capacity/Batch |
20 pcs/batch |
Consumption |
3600W |
Power Supply |
AC110/220V±10%,50/60Hz |
Packing Size(W*D*H) |
650*540*470mm |
Gross Weight |
33kg |
GCH-03 Gas Collection Hood
Exhaust System Scrubber
Features:
|
Technical Parameters:
Model |
ES402 |
Max. Flow Rate |
3m3/H |
Max. Negative Pressure |
0.05MPa |
Neutralization Methods |
Water, Alkali, and Carbon |
External Size(W*D*H) |
390*340*550mm |
Packing Size(W*D*H) |
570*440*665mm |
Gross Weight |
30.9kg |
Semi Automatic Kjeldahl Nitrogen Analyzer (Kjeldahl Distiller)
Features:
|
Technical Parameters:
Model |
BKN-983 |
Measuring Range |
0.1~250mgN |
Recovery Ratio |
≥99.5% |
Repeatability |
±0.5% |
Sample Amount |
Solid <6g, liquid <16ml |
Distillation Speed |
3~4min/sample |
Distillation Time |
0~999s |
Cooling Water Consumption |
1.2-3L/min |
Requirement of Cooling Water |
<18°C |
Consumption |
2000W |
Power Supply |
AC220V, 50/60Hz |
Packing Size(W*D*H) |
Main body: 630*540*810mm Accessories: 530*530*540mm |
Gross Weight |
Main body: 37kg Accessories: 7kg |
Fully Automatic Kjeldahl Nitrogen Analyzer
Features:
Additional Features of BKN-987A:
|
Technical Parameters:
Model |
BIN-987 |
BKN-987 |
Working Process |
Adding quantitative sample dilution, alkali liquor and absorption liquid; Automatically finishing distillation, titration, print and liquid-discharging. |
Adding quantitative sample dilution, alkali liquor and absorption liquid; Automatically finishing distillation, titration, print and liquid-discharging. |
Measurement Range |
0.1~240mgN |
0.1~240mgN |
Sample Amount |
Solid ,6g; liquid <16mI |
Solid ,6g; liquid <16mI |
Measurement Time |
4~6 minutes |
4~6 minutes |
Titration Precision |
0.75µL/step |
0.75µL/step |
Requirement of Cooling Water |
<18°C |
<18°C |
Cooling Water Consumption |
1.5L/min (Distillation process) |
1.5L/min (Distillation process) |
Titration Solution Concentration |
Direct titration samples with 4 titration concentrations of 0.1mol, 0.5moI and 1mol |
Direct titration samples with 4 titration concentrations of 0.1mol, 0.5moI and 1mol |
Titration System |
High-precision plunger type titration system |
High-precision peristaltic titration system |
Repeatability |
±0.5% |
±0.5% |
Recovery Ratio |
≥99.5% |
≥99.5% |
Data Storage |
140,000 groups |
140,000 groups |
Consumption |
2000w |
2000w |
Power Supply |
AC220V, 50/60Hz |
AC220V, 50/60Hz |
Packing Size (W*D*H) |
Main body: 630*540*810mm Accessories: 530*530*540mm |
Main body: 630*540*810mm Accessories: 530*530*540mm |
Gross Weight |
Main body: 57kg Accessories: 7kg |
Main body: 57kg Accessories: 7kg |
Kjeldahl Digestion Furnace
Technical Parameters:
Model |
BKD-8B |
Temp. Range |
RT-400°C |
Temp. Precision |
±1°C |
Heating Pipe |
Aluminum alloy pipe (Nichrome wire) |
Heating Speed |
20°C/min |
Heating Holes |
8 |
Digestion Tube Size |
300ml±0.25ml |
Consumption |
2KW |
Power Supply |
AC220V, 50/60Hz |
Packing size(W*D*H) |
660*500*295mm |
Gross weight |
20kg |