Model
Features
​BK-LCI1100
​BK-LCG1100
High Pressure Constant
Flow Pump
​Double plunger reciprocating pump
​1 set
​2 set
​High Pressure Constant
Flow Pump
Flow Range 
​0.001mL/min-10.000mL/min
​0.001mL/min-10.000mL/min
​High Pressure Constant
Flow Pump
​Setting Step Size 
0.001mL/min
0.001mL/min
​High Pressure Constant
Flow Pump
​Flow Accuracy
≤±0.3% (1.00mI/min, H2O, R.T., 8.5MPa)
≤±0.3% (1.00mI/min, H2O, R.T., 8.5MPa)
​High Pressure Constant
Flow Pump
​Flow stability
​RSD≤0.1% (1.00mI/min, H2O, R.T., 8.5MPa)
​​RSD≤0.1% (1.00mI/min, H2O, R.T., 8.5MPa)
​High Pressure Constant
Flow Pump
Maximum Pressure
42MPa
42MPa
High Pressure Constant
Flow Pump
Display Pressure Error
​≤±3 0%
​≤±3 0%
​High Pressure Constant
Flow Pump
​Pressure Fluctuation
​​​≤1%
​​≤1%
​High Pressure Constant
Flow Pump
​Power Dissipation
80KW
80KW
​UV/VIS
Detector
Wavelength Range
​190~700nm 
​​190~700nm 
​UV/VIS
Detector
​Wavelength Repeatability
±0.1nm
​±0.1nm
​UV/VIS
Detector
​Wavelength Accuracy
​≤±1.0nm
​​≤±1.0nm
​UV/VIS
Detector
​Spectrum Band Width
8nm
​8nm
​UV/VIS
Detector
​Response Time
​0.0s~4.9s
​​0.0s~4.9s
​UV/VIS
Detector
​Linearity Range 
​1.8AU (5%)
​1.8AU (5%)
​UV/VIS
Detector
Baseline Noise
≤±1x10-5 AU 
​≤±1x10-5 AU 
​UV/VIS
Detector
​Baseline Draft
​≤2.0x10-4AU/h
≤2.0x10-4AU/h
​UV/VIS
Detector
​Minimum Detectable Concentration
​4.0x10-9g/mL(Naphthalene in Methanol Solution)
​4.0x10-9g/mL(Naphthalene in Methanol Solution)
​UV/VIS
Detector
Detector Cell
Optical Path--10mm, Volume-10µL
​Optical Path--10mm, Volume-10µL
​UV/VIS
Detector
​Light Source
​Deuterium Lamp
​Deuterium Lamp
UV/VIS
Detector
​Power Dissipation
​100W
​100W
 
​Gradient Mixer
/
​GM1100
 
Sampler Injector
1​
​1
 
Supersil ODS2 5µm ID4.6x200mm
​1
​1
 
​Workstation
​(Without Computer & Printer)
​1
​1
 
Valve Mounting Frame
​1
​1
 
​Kits
​Isocratic System Kits
Gradient System Kits
 
Power Supply
​AC110/220V±10%, 50/60Hz
​AC110/220V±10%, 50/60Hz
 
Optional Accessory
​Solvent bottle, Column, Column Oven, PC
​Solvent bottle, Column, Column Oven, PC
 
Package Size (W*D*H)
600*440*380mm,
600*410*300mm*2
600*440*380mm,
600*410*300mm*3
 
​Gross Weight
​54kg
​75kg

High Performance Liquid Chromatography

Picture
Features:
  • Adopting mature and reliable mechanical structure, optical structure, and circuit structure of core technology,
  • Stepper motor 64 subdivision control technology to improve accuracy at low flow rates
  • Straight-through pressure transmitter
  • Scientific air duct design to effectively reduce baseline drift
Technical Parameters:
Model
Description
BK-LCI3100
​BK-LCGH3100
BK-LCQL3100
​High Pressure Constant Flow Pump
​Quantity
​1 Set
2 sets
​1 Set
​High Pressure Constant Flow Pump
Flow Rate Range
​0.001mL/min-10.000mL/min
​0.001mL/min-10.000mL/min
0.001mL/min-10.000mL/min
​High Pressure Constant Flow Pump
​Flow Accuracy 
≤±0.2% (1.00mI/min, H2O, R.T., 8.5MPa)
​≤±0.2% (1.00mI/min, H2O, R.T., 8.5MPa)
≤±0.2% (1.00mI/min, H2O, R.T., 8.5MPa)
​High Pressure Constant Flow Pump
​Flow Precision
​RSD 0.075% (1.00mI/min, H20, R.T., 8.5MPa)
​​RSD 0.075% (1.00mI/min, H20, R.T., 8.5MPa)
​RSD 0.075% (1.00mI/min, H20, R.T., 8.5MPa)
​High Pressure Constant Flow Pump
Maximum Pressure
​45MPa
​45MPa
​45MPa
​High Pressure Constant Flow Pump
​Pressure accuracy
​≤±3.0%
​≤±3.0%
​≤±3.0%
High Pressure Constant Flow Pump
Pressure pulsation 
≤0.1MPa
​≤0.1MPa
≤0.1MPa
​UV/VIS
Detector
Wavelength Range
​190~700nm
​190~700nm
​190~700nm
​UV/VIS
Detector
​Wavelength Repeatability
​≤0.1nm
​≤0.1nm
​≤0.1nm
​UV/VIS
Detector
Wavelength Accuracy
​≤±1.0nm
​≤±1.0nm
​≤±1.0nm
​UV/VIS
Detector
​Band Width
​8nm
​8nm
8nm
​UV/VIS
Detector
Response Time
​0.0s-5s
​0.0s-5s
​0.0s-5s
​UV/VIS
Detector
​Baseline Noise
≤±0.5x10-5AU
​≤±0.5x10-5AU
​≤±0.5x10-5AU
UV/VIS
Detector
​Drift
≤±1.0x10-4AU/h
​≤±1.0x10-4AU/h
​≤±1.0x10-4AU/h
​UV/VIS
Detector
Path length
​10 mm(analytical cell)
​10 mm(analytical cell)
10 mm(analytical cell)
​UV/VIS
Detector
​Light Source
​Deuterium Lamp
​Deuterium Lamp
Deuterium Lamp
​Low- Pressure Gradient
Unit
​Integrated vacuum degasser
/
/
​4 channels
​Low- Pressure Gradient
Unit
Composition Rang
/
/
0-100%
​Low- Pressure Gradient
Unit
​Composition Precision
/
/
​≤0.2% RSD
Low- Pressure Gradient
Unit
​Composition Accuracy
/
/
​≤±2.0%
 
​Data-processing Workstation
​♦Internal and external standard calculation methods.
♦ Automatically displays, prints, exports, and starts other programs after the completion of a measurement.
♦Comply with the requirements of the 21 CFR Part 11 directive of the FDP.
​♦Internal and external standard calculation methods.
♦ Automatically displays, prints, exports, and starts other programs after the completion of a measurement.
♦Comply with the requirements of the 21 CFR Part 11 directive of the FDP.
​♦Internal and external standard calculation methods.
♦ Automatically displays, prints, exports, and starts other programs after the completion of a measurement.
♦Comply with the requirements of the 21 CFR Part 11 directive of the FDP.
 
3100 System Kits
​1 Set
​1 Set
​1 Set
 
​Power Supply
AC110/220V±10%, 50/60H
AC110/220V±10%, 50/60Hz
​AC110/220V±10%, 50/60Hz
 
Optional Accessory
​Solvent bottle, Column, Column Oven, Auto-sampler, DAD512 Detector,
RI-201HDetector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector, PC
​Solvent bottle, Column, Column Oven, Auto-sampler, DAD512 Detector,
RI-201HDetector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector, PC
​Solvent bottle, Column, Column Oven, Auto-sampler, DAD512 Detector,
RI-201HDetector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector, PC
 
​Package Size(W*D*H)
​600*440*380mm*4
​600*440*380mm*4
600*440*380mm*4
 
Gross Weight
​68kg
​68kg
​68kg

High Performance Liquid Chromatography

Picture
Features:
  • Highly integrated ARM microcontroller SPI, l2C technology.
  • Accurate automatic wavelength positioning and excellent wavelength accuracy.
  • Plunger floating design, more stable output.
  • Intelligent sequence analysis and batch processing.
  • Chromatography workstation software meets 21 CFR Part 11.
Technical Parameters:
Model
 
​BK-LCI5100
BK-LCG5100
​BK-LCQL5100
​Pump
Type
Isocratic Pump
Gradient Pump
Quaternary Low Pressure Pump
​Pump
​Flow Rate Range
​0.001~10.000mL/min, in 0.001mL increments
​0.001~10.000mL/min, in 0.001mL increments
​0.001~10.000mL/min, in 0.001mL increments
​Pump
​Flow Accuracy
≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
​Pump
Flow Precision
RSD≤0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
​RSD≤0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
​RSD≤0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
​Pump
Maximum Pressure
​63MPa
63MPa
63MPa
​Pump
​Pressure accuracy 
​≤±3.0%
​≤±3.0%
≤±3.0%
​Pump
​Pressure pulsation
​≤0.1MPa
​≤0.1MPa
≤0.1MPa
​Pump
Composition rang
/
0~100%
​0~100%
​Pump
Composition precision
/
≤0.2%RSD
​≤0.3%RSD
​UV/VIS
Detector
​Wavelength Range
​190~800nm
​190~800nm
​190~800nm
​UV/VIS
Detector
​Wavelength Repeatability 
​≤0.1nm 
​≤0.1nm 
​≤0.1nm 
​UV/VIS
Detector
​Wavelength Accuracy
​≤±1.0nm
​≤±1.0nm
≤±1.0nm
​UV/VIS
Detector
​Band Width
​6nm
​6nm
​6nm
​UV/VIS
Detector
Response Time
​0.0s-5s
​0.0s-5s
​0.0s-5s
​UV/VIS
Detector
 Baseline Noise
​≤±0.25x10-5AU(empty cell, 254nm, 1.0s)
​≤±0.25x10-5AU(empty cell, 254nm, 1.0s)
​≤±0.25x10-5AU(empty cell, 254nm, 1.0s)
​UV/VIS
Detector
​Drift
​≤0.5x10-4AU/h(empty cell, 254nm, 60min)
​≤0.5x10-4AU/h(empty cell, 254nm, 60min)
​≤0.5x10-4AU/h(empty cell, 254nm, 60min)
​UV/VIS
Detector
​Path length
​10 mm (analytical cell)
​10 mm (analytical cell)
10 mm (analytical cell)
UV/VIS
Detector
​Light Source
​Deuterium Lamp and Tungsten Lamp
​Deuterium Lamp and Tungsten Lamp
​Deuterium Lamp and Tungsten Lamp
 
​​Data-processing Workstation
​♦Sequence tables for any set of samples.
♦Internal and external standard calculation methods.
♦Automatically displays, prints, exports, and starts other programs after the completion of a measurement.
♦Comply with the requirements of the 21 CFR Part 11 directive of the FDA
​​♦Sequence tables for any set of samples.
♦Internal and external standard calculation methods.
♦Automatically displays, prints, exports, and starts other programs after the completion of a measurement.
♦Comply with the requirements of the 21 CFR Part 11 directive of the FDA
​​♦Sequence tables for any set of samples.
♦Internal and external standard calculation methods.
♦Automatically displays, prints, exports, and starts other programs after the completion of a measurement.
♦Comply with the requirements of the 21 CFR Part 11 directive of the FDA
 
​​5100 System Kits
​1 Set
​1 Set
​1 Set
 
​5100 System Manager
​Integrated A/D converters
Integrated A/D converters
​Integrated A/D converters
Integrated vacuum degasser, 4 channel
 
​​Power Supply
​AC110/220V±10%, 50/60Hz
​AC110/220V±10%, 50/60Hz
AC110/220V±10%, 50/60Hz
 
​Optional Accessory
​Solvent bottle, Column, Column Oven, Auto-sampler, DAD512 Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector, PC.
​Solvent bottle, Column, Column Oven, Auto-sampler, DAD512 Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector, PC.
​Solvent bottle, Column, Column Oven, Auto-sampler, DAD512 Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector, PC.
 
​Package Size (W*D*H)  
​700*570*310mm; 700*570*350mm; 710*583*500mm;
730*450*440mm: 600*440*380mm: 770*450*700mm
​700*570*310mm; 700*570*350mm; 710*583*500mm;
730*450*440mm: 600*440*380mm: 770*450*700mm
700*570*310mm; 700*570*350mm; 710*583*500mm;
730*450*440mm: 600*440*380mm: 770*450*700mm
 
Gross Weight
​156kg
​156kg
​156kg
Optical Columns:
​Column
name
​Model
Granularity (µm)
​Specification (mm)
Column name
Model
Granularity (µm)
Specification (mm)
​Supersil ODS2
31113001
​5
​2.1”150
​Supersil 120ASCX
​31113078
5
​4.6”150
​Supersil ODS2
​31113002
​5
4.6*150
​Supersil 120ASCX
31113079
​5
4.6*200
​Supersil ODS2
31113003
​5
​4.6*200
​Supersil 120ASCX
​31113080
5
​4.6*250
​Supersil ODS2
​31113004
​5
4.6*250
Supersil 120ASCX
31113081
5
4.6”300
​Supersil ODS2
31113005
​5
​4.6*300
​Supersil 300ASCX
​31113082
5
​4.6*150
​Supersil ODS2
​31113065
3
4.6*50
​Supersil 300ASCX
31113083
​5
4.6*200
​Supersil ODS2
31113066
​3
​4.6*100
​Supersil 300ASCX
​31113084
​5
​4.6*250
​Supersil ODS2
31113067
​3
4.6*150
Supersil 300ASCX
31113085
​5
4.6*300
​Supersil ODS2
31113068
​3
​2.1*50
​Supersil AQ-C18
​31113057
​5
​4.6*150
​Supersil ODS2
31113069
​3
2.1*100
​Supersil AQ-C18
31113058
5
4.6*200
​Supersil ODS-B
31113034
​5
2.1*150
​Supersil AQ-C18
​31113059
​5
4.6”250
​Supersil ODS-B
​31113043
​5
4.6”100
Supersil AQ-C18
31113060
​5
4.6*300
​Supersil ODS-B
31113039
​5
4.6“150
​Supersil Phenyl
​31113094
​5
​2.1*150
​Supersil ODS-B
​31113040
​5
4.6*200
​Supersil Phenyl
31113086
​5
4.6*150
​Supersil ODS-B
31113041
​5
4.6*250
​Supersil Phenyl
​31113087
​5
​4.6*200
​Supersil ODS-B
31113042
​5
4.6*300
​Supersil Phenyl
​31113088
​5
4.6*250
​Supersil ODS-B
31113044
​5
4.0“100
Supersil Phenyl
​31113089
​5
​4.6”300
​Supersil ODS-B
​31113035
​5
4.0*150
​Supersil NH2
31113074
​5
4.6*150
​Supersil ODS-B
​31113036
​5
4.0”200
​Supersil NH2
​31113075
​5
​4.6*200
​Supersil ODS-B
31113037
​5
4.0*250
​Supersil NH2
31113076
​5
4.6*250
​Supersil ODS-B
​31113038
​5
​4.0*300
Supersil NH2
​31113077
​5
​4.6*300
​Supersil C8
31113053
​5
​4.6*150
​Supersil NH2-S
31113090
​5
4.6*150
​Supersil C8
​31113054
​5
4.6*200
​Supersil NH2-S
​31113091
​5
​4.6*200
​Supersil C8
31113055
​5
​4.6*250
​Supersil NH2-S
31113092
​5
4.6*250
Supersil C8
​31113056
​5
4.6*300
Supersil NH2-S
​31113093
​5
​4.6*300
​Supersil 120A C4
31113061
​5
​4.6*150
​Supersil CN
31113070
​5
4.6*150
​Supersil 120A C4
​31113062
​5
4.6*200
​Supersil CN
​31113071
​5
​4.6*200
​Supersil 120A C4
31113063
​5
4.6*250
​Supersil CN
31113072
5
4.6*250
Supersil 120A C4
31113064
​5
4.6*300
Supersil CN
​31113073
​5
4.6*300
​Supersil 300A C4
31113049
​5
​4.6*150
​Supersil SiO2
31113045
​5
4.6*150
​Supersil 300A C4
​31113050
​5
4.6*200
​Supersil SiO2
​31113046
​5
4.6*200
​Supersil 300A C4
31113051
​5
4.6*250
​Supersil SiO2
31113047
​5
4.6*250
​Supersil 300A C4
31113052
5
​4.6*300
Supersil SiO2
​31113048
5
​4.6*300
Note: we have more columns, and the listed models are for your reference.