Gas Chromatograph

Picture
​Features:
  • 7-inch LCD display indicates temperature, gas flow and heating curve.
  • Self-test function and automatic fault recognition function.
  • 8 pcs external extension interfaces can connect with control valve.
  • Equipped with a flame ionization detector (FID).
  • Multi-core and 32-bit embedded hardware system ensures the reliable operation.
  • Synchronous external trigger function and the external signal (auto sampler, thermal analyzer, etc.) can start the equipment and workstation software at the same time.
  •  With chromatography workstation software to process data.
  • Memory function. can store 20 sample test modes.
  • One-key start up function.
Technical Parameters:
Model
BK-GC112
 
​Oven
Capacity
22L
​Oven
Temp. Range
​RT+5°C~400°C
​Oven
Temp. Accuracy
± 0.1°C
Oven
Temp. Program
9 step
​Oven
Program Total Time
9999.9 min 
​Oven
​Max Temp. Heating Rate
60°C/min 
​Sample Injector
​Temp. Range
​RT+7°C~420°C
​Sample Injector
Column or split injector can be installed 
 
​Sample Injector
​Carrier gas flow control type 
Constant pressure mode
​Sample Injector
​Max. Quantity
​3pcs
​Sample Injector
Pre Column Pressure Range
0-400kpa
​Sample Injector
Pre Column Pressure Accuracy 
​0.1kpa
​Sample Injector
​Flow Setting Range
H2 0-200ml/min
​N2: 0-150ml/min 
​Detector
​Temp. Range
RT+7°C~420°C
​Detector
​Hygrogen Flame Ionization Detector (FID)
  • ​Longarithmic amplifier
  • High voltage seitch control 
  • Baseline signal display
  • Detection limit: ≤3*10-12g/s (Sample: n-hexadecane) 
  • Baseline noise: ≤5*10-14A
  • Baseline draft: ≤6*10-13A
  • Dynamic range: 107
  • RSD: ≤3%
​​Detector
​Thermal Conductivity
Detector (TCD)(Optional)
  • Sensitivity: 8000mv.ml/mg (Sample: n-hexadecane)
  • Baseline noise: ≤0.05mV
  • Baseline draft: ≤0.15mV/30min
  • Dynamic range: 105
​Power Supply
​AC220V±10%, 50Hz
 
​Standard Accessory
​FID detector, Capillary injection system, Chromatography workstation software, RS232 port, LAN port
 
Optional Accessory
TCD detector, Chromatographic column, Gas purifier
 
Package Size(W*D*H)
740*730*840mm
​ 
​Gross Weight
​80kg
 

Gas Chromatograph

Picture
Features:
  • 5.7-inch LCD display indicates temperature, time, and gas flow.
  • Can install packed column and capillary column at the same time                                                                             
  • Self-test, power protection, keyboard lock, automatic ignition and anti power mutation interference function
  • With chromatography workstation software to process data.
  • Equipped with a flame ionization detector (FID), and TCD, ECD, FPD, NPD are optional. Can install 3 detectors at the same time.
  • Can connect with Internet, realize data transfer, and program upgrade automatically.                                 ””
  • Double column compensation function, which can effectively restrain baseline drift and the influence of background noise
  • Large capacity oven (300*2B0*180mm) can hold 2 pcs 0.32mm diameter capillary column (length: 80m).
  • Better thermal insulation effect. when the temp. of oven, vaporizing chamber and detector reach 300°C, the max. temp. of outer chamber is 40°C.
Technical Parameters:
​Model
BK-GC7820
  
​Oven
​Temp. Range
RT~450°C
​Oven
​Temp. Accuracy
​≤±0.1°C
​Oven
Temp. Program
​16-phase
​Oven
​Max. Temp. Heating Rate
40°C/min
​Detector
Hydrogen Flame Ionization Detector (FID)
  • Detection limit: ≤3*10-12g/s (Sample: n-hexadecane)
  • Baseline drift: ≤1*10-13A/30min 
  • Linier range: ≥107
​Detector
Thermal Conductivity Detector (TCD) (Optional)
  • Sensitivity: >1000mv.ml/mg (Sample: n-hexadecane)
  • Linier range: ≥105
​Detector
​Electron Capture Detector (ECD) (Optional)
  • ​Detection limit: ≤1*10-14g/ml (Sample: n-hexadecane)
  • Linier range: ≥104
​Detector
Flame Photometric Detector (FPD) (Optional)
  • Detection limit: ≤2*10-11g/s (S of thiophene)
  • Detection limit: ≤1*10-12g/s (P of methyl parathion)
  • Limit range (S): ≥103
  • Limit range (P): ≥104
​Detector
​Nitrogen and Phosphorus Detector (NPD) (Optional)
  • Detection limit: ≤1*10-12g/s (Azobenzene)
  • Detection limit: ≤1*10-12g/s (Maria sulphur phosphorus)
  • Linier range: ≥103
​Power Supply
AC110/220V±10%, 50/60Hz
  
Standard Accessory
​FID detector, Chromatography workstation software
  
​Optional Accessory
​Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column
  
Package Size (W*D*H)
​800*570*650mm
  
​Gross Weight
​75kg
 