TRIVANCED PTE. LTD. - Laboratory, Semiconductor and Medical Equipment Supplies and Accessories in Singapore - Furnace, Oven, Chamber, Freezer, Refrigerator, Incubator, Sterilizer, Sterilization, Dehumidifier, Vacuum

  • Home
  • About
  • Products
  • Services
  • Contact
  • Home
  • About
  • Products
  • Services
  • Contact

​Fat Analyzer

Picture
BFA-1S Fat Analyzer, designed based on the Soxhlet extraction principle, is an automatic crude fat analyzer in which weight method is used to determine the fat content.
Features:
  • Automatic process after weighting the sample.
  • 8" LCD Touch screen control panel, easy to operate. Five extraction methods: Soxhlet standard extraction,
  • Soxhlet hot extraction, continue flow extraction, hot extraction, Soxhlet CH standard method.
  • Ether leakage automaticalarm.
  • Water temperature and water flow monitoring
  • Automatic solvent recovery.
Technical Parameters:
Model
​BFA-1S
​Temp. Range
​RT+54~300°C
​Measuring Range
​0.1~100%
​Temperature Accuracy
​±1°C
​Repeatability
​Relative error 1%
​Sample Weight
0.5~15g
Capacity
​6pcs/batch
​Solvent Cup Volume
150mI
Solvent Recovery
​≥85%
​Consumption
2.0KW
Power Supply
​AC220V±10%, 50Hz
​External Size(W*D*H)
650*348*875mm
​Package Size(W*D*H)
​Main Body: 835*540*930mm / Accessories: 450*310*245mm
​Gross Weight
Main Body: 92kg / Accessories: 4.5kg

Fat Analyzer

​BFA-2 Fat Analyzer is based on the Soxhlet extraction principle and integrates such functions as soaking, extraction, leaching, heating, condensation, and solvent recovery.
Picture
Features:
  • 4.3" LCD screen and Microcomputer control system.
  • Integral dry heating, wide scope and high precision of temperature control.
  • Electric circuit is isolated from the extraction space, ensuring devices security.
  • Over-temperature alarm and timer reminding functions.
  • Abundant interface contents give simultaneous display of set temperature, actual temperature, set time and
  • heating time.
  • Unique air insulation for temperature heating protection and constant temperature.
Technical Parameters:
Model
BFA-2
Temp. Range
​RT+5°C-300°C
​Measuring Range
0~100%
Temperature Accuracy
±1°C
​Sample Weight
​0.5~15g (generally 2~5g, depending on sample)
Capacity
​6pcs/batch
Solvent Cup Volume
​80ml
Solvent Recovery
​≥80%
​Consumption 
​1KW
Power Supply
​AC 220V±10%, 50HZ 
​External Size(W*D*H)
​650*320*715mm
​Package Size(W*D*H)
735*410*880mm
Gross Weight
​54.5kg